Diagnostic Yield and Safety Profile of Shape-Sensing Robotic-Assisted Bronchoscopy in Peripheral Pulmonary Nodules 8 mm or Smaller.
Sebastian Fernandez-Bussy, Regina M Murillo-Torres, Alejandra Yu Lee-Mateus, Tatiana A Rojas-Zapata, Deepika Karki, Lorna Evans, Mohammed A Alqawasma, Ryan M Chadha,
Division of Pulmonary, Allergy, Sleep and Respiratory Medicine, Mayo Clinic, Jacksonville, FL, United States of America. fernandez-bussy.sebastian@mayo.edu. · Division of Pulmonary, Allergy, Sleep and Respiratory Medicine, Mayo Clinic, Jacksonville, FL, United States of America.
Key points
From the paper's conclusion- A total of 195 nodules were included in the study. Median lesions diameter was seven mm (IQR 6-8). Strict diagnostic yield was 70.2% (137/195), while intermediate diagnostic yield was 77.4% (151/195). Malignancy was identified in 104 lesions (53.3%). The median ssRAB procedure time was 59 min (IQR 45-83). Pneumothorax occurred in six patients (3.3%), with chest tube placement required in two (1.1%).
Abstract
PURPOSE: Lung cancer screening guidelines generally recommend imaging surveillance rather than tissue sampling for nodules measuring ≤8 mm. Evidence regarding the feasibility, diagnostic performance, and safety of tissue biopsy in this lesion size remains limited. We evaluated the diagnostic performance and safety of shape-sensing robotic-assisted bronchoscopy (ssRAB) for biopsy of peripheral pulmonary nodules measuring ≤8 mm. METHODS: We conducted a retrospective single-center study of consecutive patients who underwent ssRAB between June 2020 and December 2025 for biopsy of nodules measuring ≤8 mm on pre-procedural CT imaging. The primary outcome was strict diagnostic yield, as defined by the American Thoracic Society/American College of Chest Physicians. Secondary objectives included intermediate diagnostic yield, diagnostic distribution, procedural outcomes, and complications. Diagnostic performance according to lesion size (≤ 6 mm vs. 6.1-8 mm) was evaluated separately as a subgroup analysis. RESULTS: A total of 195 nodules were included in the study. Median lesions diameter was seven mm (IQR 6-8). Strict diagnostic yield was 70.2% (137/195), while intermediate diagnostic yield was 77.4% (151/195). Malignancy was identified in 104 lesions (53.3%). The median ssRAB procedure time was 59 min (IQR 45-83). Pneumothorax occurred in six patients (3.3%), with chest tube placement required in two (1.1%). DISCUSSION: Shape-sensing robotic-assisted bronchoscopy demonstrated meaningful diagnostic performance and a favorable safety profile for peripheral pulmonary nodules measuring ≤8 mm, including lesions ≤6 mm. In this selected, higher-risk cohort, our findings suggest that earlier tissue diagnosis can be feasible and may benefit some patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tool in lesion verification of shape-sensing robotic-assisted bronchoscopy with cone beam CT in sampling peripheral pulmonary nodulesThorax · 2025
- Diagnostic Performance and Safety Profile of Shape-sensing Robotic-assisted Bronchoscopy in Peripheral Pulmonary Lesions: A Systematic Review and Meta-Analysis.Respiration; international review of thoracic diseases · 2026
- Diagnostic Efficiency of Sequential Tissue Acquisition During Shape-Sensing Robotic-Assisted Bronchoscopy in a Thoracic Surgery Setting: A Biopsy-Level Analysis.Diagnostics (Basel, Switzerland) · 2026
- First Korean experience with shape-sensing robotic-assisted bronchoscopy integrated with mobile cone-beam CT: Results from the prospective ULSAN-ION study.Lung cancer (Amsterdam, Netherlands) · 2026
- Sensitivity for Malignancy with Navigation Bronchoscopy in Small Lung Nodules.Advances in respiratory medicine · 2026
- Robotic-Assisted Bronchoscopy for Peripheral Pulmonary Lesions: Current Evidence, Clinical Applications, and Future Directions.Diagnostics (Basel, Switzerland) · 2026