Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology

Contrast-enhanced echocardiographic assessment of left ventricular wall measurements in cats.

J Novo Matos, I Harding, C Partington

Department of Veterinary Medicine, University of Cambridge, Madingley Road, Cambridge CB3 0ES, England, United Kingdom. Electronic address: jms330@cam.ac.uk. · Department of Veterinary Medicine, University of Cambridge, Madingley Road, Cambridge CB3 0ES, England, United Kingdom.

Observational

Key points

From the paper's conclusion
  • Standard echocardiography seems to overestimate LVWT compared to C-ECHO, consistent with findings reported in human studies. Contrast-enhanced echocardiography improves measurement reliability. These findings support its use to enhance HCM assessment in cats.

Abstract

INTRODUCTION/OBJECTIVES: Hypertrophic cardiomyopathy (HCM) is defined by increased left ventricular wall thickness (LVWT), making accurate measurement essential. Contrast-enhanced echocardiography (C-ECHO) improves myocardial border delineation. We aimed to evaluate whether C-ECHO provides more reliable LVWT measurements in cats than standard echocardiography (S-ECHO). ANIMALS, MATERIALS AND METHODS: Forty-five cats (32 with an LVWT <6 mm and 13 with an LVWT ≥6 mm) were prospectively enrolled in the study. Two-dimensional right parasternal short-axis images were acquired before and after contrast administration (SonoVue: 0.05 mL/kg [0.04-0.14 mL/kg]). Septal and posterior wall thickness values were measured using both modalities. Agreement and reliability were assessed using Bland-Altman analysis, Kappa statistics, and intraclass correlation coefficients. RESULTS: Left ventricular wall thickness was greater with S-ECHO than C-ECHO (maximal LVWT: 5.0 mm [2.8-9.5 mm] vs. 4.2 mm [2.5-8.9 mm], P < 0.0001). On average, the LVWT measured by S-ECHO was 0.61 mm greater than that obtained by C-ECHO. Agreement between S-ECHO and C-ECHO for HCM diagnosis was only moderate (Kappa: 0.50). The Bland-Altman analysis showed fixed biases and wide 95% limits of agreement (LoA) for LVWT (septum: bias: 0.8 mm, LoA: -0.7-2.3 mm; posterior wall: bias: 0.4 mm, LoA: -1.1-2.0 mm). Contrast-enhanced echocardiography demonstrated higher measurement reliability (intraclass correlation coefficient: 0.99 vs. 0.96). STUDY LIMITATIONS: A low-mechanical index preset was not used, and measurements were not timed using an electrocardiogram (ECG). CONCLUSIONS: Standard echocardiography seems to overestimate LVWT compared to C-ECHO, consistent with findings reported in human studies. Contrast-enhanced echocardiography improves measurement reliability. These findings support its use to enhance HCM assessment in cats.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers