Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology

The use of contrast-enhanced echocardiography in the evaluation of feline left ventricular wall thickness.

E Javery, S Kadotani, C Toborowsky, S Prabhakar, T Sumerfield, K Selting, R Fries

Department of Veterinary Clinical Medicine, University of Illinois, 1008 West Hazelwood Drive, Urbana, IL, 61802, USA. · Department of Veterinary Clinical Medicine, University of Illinois, 1008 West Hazelwood Drive, Urbana, IL, 61802, USA. Electronic address: rfries@illinois.edu.

Observational

Key points

From the paper's conclusion
  • Contrast-enhanced echocardiography is feasible and provides excellent left ventricular wall visualization with lower LVWT measurements and superior repeatability, reproducibility, and reliability.

Abstract

INTRODUCTION/OBJECTIVES: Accurate measurement of feline left ventricular wall thickness (LVWT) is challenging due to endocardial and myocardial irregularities, false tendons, and prominent papillary muscles. In human medicine, contrast-enhanced echocardiography (C-Echo) is used to improve left ventricular wall delineation and is more accurate, repeatable, and reliable than standard echocardiography (S-Echo). Our objective was to compare C-Echo and S-Echo measurements of feline LVWT and determine repeatability, reproducibility, and reliability of each modality. ANIMALS, MATERIALS AND METHODS: Fifty client-owned cats were prospectively enrolled in the study. Cats underwent S-Echo and C-Echo after intravenous injection of contrast agent. Methods were compared using Bland-Altman and Passing-Bablok regression. Interoperator and intra-operator reproducibility, repeatability, and reliability were quantified using intraclass correlation coefficients, repeatability coefficients, and coefficients of variation. RESULTS: Standard echocardiography and C-Echo differed significantly for all segments with a median difference of 0.56 mm (range: -1.4 to 4.9 mm; P<0.0001). Regression showed proportional bias (slope: 1.21, confidence interval: 1.11-1.31) with minimal systematic bias (intercept: -0.26, confidence interval: -0.64 to 0.12). Intra-operator and interoperator reproducibility was excellent for both modalities (intraclass correlation coefficient: 0.90-0.94 for S-Echo; 0.86-0.99 for C-Echo), while repeatability coefficients were lower for C-Echo (0.28-0.61 mm) than for S-Echo (0.89-1.03 mm), and coefficients of variation were lower for C-Echo (intra-observer: 5.86%, inter-observer: 3.03%) than for S-Echo (7.43% and 7.64%). STUDY LIMITATIONS: Accuracy of S-Echo and C-Echo compared with a reference standard was not assessed. CONCLUSIONS: Contrast-enhanced echocardiography is feasible and provides excellent left ventricular wall visualization with lower LVWT measurements and superior repeatability, reproducibility, and reliability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers