The Lateralization and Distalization Shoulder Angles in Reverse Total Shoulder Arthroplasty Are Highly Sensitive to Both Arm Position and Viewing Angle: Analyzed Using the Enovis Altivate and Surgicase.
Liam T Kane, Surena Namdari, Michael Amini
Rothman Orthopaedic Institute at Thomas Jefferson University HospitalsPhiladelphia, PA. · Rothman Orthopaedic Institute at Thomas Jefferson University HospitalsPhiladelphia, PA. Electronic address: michael.amini@jefferson.edu.
Key points
From the paper's conclusion- The commonly utilized parameters LSA and DSA show significant variability with and sensitivity to both arm position and viewing angle. Linear measurements of lateralization and distalization are less sensitive to these changes.
Abstract
BACKGROUND: In reverse total shoulder arthroplasty (rTSA), the lateralization shoulder angle (LSA) and distalization shoulder angle (DSA) are very prevalent in clinical research and clinical practice to measure the geometry of the implant construct. The purpose of this study was to determine whether LSA and DSA are impacted by changes in 1) resting arm angle (RAA) and 2) radiographic viewing angle. Secondarily, the study evaluated if linear measures of lateralization and distalization are less sensitive to these changes than LSA and DSA. METHODS: This was a computer modeling study using commercially available preoperative planning three-dimensional software (Materialise Surgicase). Ten patients without glenoid bone loss undergoing rTSA were included. Four distinct implant constructs (Enovis Altivate Reverse®) were placed in each patient, resulting in 40 total plans. For each plan, thirteen unique viewing profiles were generated to establish variability in the following measurements: LSA, DSA, humeral distalization (acromiohumeral interval (AHI)), and humeral lateralization (distance from glenosphere center of rotation to greater tuberosity (GT-COR)). For each measurement, a one-way analysis of variance (ANOVA) and Pearson's r evaluated its variability by change in viewing profile. Additionally, the humeral position and viewing angle that provided the largest discrepancy in LSA and DSA values were combined and measured to evaluate maximum variability. RESULTS: LSA measurements were significantly impacted by changes in RAA (r=0.383; p<0.001) and increases in viewing angle: medial tilt (r=0.284; p=0.006), lateral tilt (r=-0.400; p<0.001), and superior tilt (r=0.509; p<0.001). Similarly, DSA measurements were significantly altered by changes in RAA (r=-0.454; p<0.001) and viewing angle: medial tilt (r=-0.282; p=0.005), lateral tilt (r=0.419; p<0.001), and superior tilt (r=-0.328; p=0.001). Neither LSA nor DSA measurements were affected by changes in humeral rotation or inferior tilt. The difference between the smallest and largest measurements was on average 35.8° (R: 28.3°-48°) for LSA and 34.6° (R: 20.9°-52.8°) for DSA. Changes in AHI were found to be correlated with changes in RAA (r=-0.588; p<0.001) and increases in superior tilt only (r=-0.259; p=0.017). GT-COR measurements were not impacted by RAA, humeral rotation, or viewing angle. CONCLUSION: The commonly utilized parameters LSA and DSA show significant variability with and sensitivity to both arm position and viewing angle. Linear measurements of lateralization and distalization are less sensitive to these changes. LEVEL OF EVIDENCE: Basic Science Study, Validation of Computer Modeling Software.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The impact of lateralization and distalization shoulder angles-A systematic review of range of motion and clinical outcomes following reverse shoulder arthroplasty.Shoulder & elbow · 2026
- Scapular posture estimation from manual palpation of anatomical landmarks: An uncertainty and sensitivity analysis.Journal of biomechanics · 2026
- Reverse Shoulder Arthroplasty with a Glenoid-Sided Lateralized Prosthesis and Concomitant Latissimus Dorsi Transfer Is Associated with Early Proximal Humeral Osseous Erosion Without Superior Functional Outcomes.Journal of shoulder and elbow surgery · 2026
- Customized positioning of the glenoid component in reverse shoulder arthroplasty: a new computer aided design methodologyInternational Orthopaedics · 2026
- Scapular upward rotation during intraoperative functional zero-position assessment in relation to postoperative outcomes and elevated alignment after reverse total shoulder arthroplasty.International orthopaedics · 2026
- A Novel Tabletop Plane-Based Scapular Coordinate System Improves the Reproducibility of Preoperative Three-Dimensional Measurements in Reverse Total Shoulder Arthroplasty.Journal of clinical medicine · 2026