A Novel Tabletop Plane-Based Scapular Coordinate System Improves the Reproducibility of Preoperative Three-Dimensional Measurements in Reverse Total Shoulder Arthroplasty.
Tomoya Manaka, Katsumasa Nakazawa, Yukihide Minoda, Rei Nishiura, Eriki Yanagi, Suguru Mori, Taisuke Nozu, Yoshihiro Hirakawa,
Department of Orthopaedic Surgery, Graduate School of Medicine, Osaka Metropolitan University, Osaka 545-8585, Japan. · Department of Orthopaedic Surgery, Osaka Orthopedic Hospital, Osaka 553-0007, Japan.
Key points
From the paper's conclusion- Conclusions: The ASP coordinate system demonstrated superior reproducibility compared with the conventional SSP coordinate system for preoperative 3D evaluation of glenoid morphology.
Abstract
Background/Objectives: Accurate three-dimensional (3D) assessment of glenoid morphology depends on the coordinate system used for measurement. Conventional landmark-based coordinate systems may be affected by observer-dependent variability in identifying the scapular landmarks. This study aimed to compare the reproducibility of a novel anterior scapular plane (ASP) coordinate system with that of the conventional surgical scapular plane (SSP). Methods: Twenty-five shoulders undergoing primary reverse total shoulder arthroplasty were evaluated using preoperative computed tomography scans. Glenoid version (GV), glenoid inclination (GI), glenoid height (GH), glenoid width (GW), and global offset (GO) were measured using both coordinate systems. Two fellowship-trained shoulder surgeons independently performed all measurements twice at a 1-month interval. Intra- and inter-observer reliability were assessed using intraclass correlation coefficients (ICCs). Results: ASP demonstrated almost perfect intra- and inter-observer reliability for all parameters, with ICCs ranging from 0.888 to 0.990 and from 0.864 to 0.932, respectively. In contrast, SSP demonstrated almost perfect intra-observer reliability (ICC range, 0.815-0.963) but only substantial inter-observer reliability for GV (ICC range, 0.660-0.705) and GI (ICC range, 0.660-0.738). Using ASP, inter-observer reliability improved to 0.887-0.924 for GV and 0.898-0.932 for GI. Conclusions: The ASP coordinate system demonstrated superior reproducibility compared with the conventional SSP coordinate system for preoperative 3D evaluation of glenoid morphology. Its anatomical accuracy and applicability to postoperative assessment remain to be validated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Scapular posture estimation from manual palpation of anatomical landmarks: An uncertainty and sensitivity analysis.Journal of biomechanics · 2026
- Customized positioning of the glenoid component in reverse shoulder arthroplasty: a new computer aided design methodologyInternational Orthopaedics · 2026
- Intra- and Interobserver Reliability of the CT-Based Glenoid Arc-Angle Method Using Injured-Side and Contralateral Reference Circles: A Diagnostic Reliability Study.Diagnostics (Basel, Switzerland) · 2026
- Scapular Morphology and Posterior Shoulder Stability: Biomechanical Evidence From an Advanced Cadaveric Shoulder SimulatorThe American Journal of Sports Medicine · 2026
- Reliability of Implant- vs. Bone-Based Postoperative Measurements After Anatomic Total Shoulder Arthroplasty Using CT Imaging.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- Three-Dimensional CT-Based Simulation of Four Central Peg Placement Strategies for a Reverse Glenoid Baseplate.Journal of visualized experiments : JoVE · 2026