Journal of the Society for Cardiovascular Angiography & Interventions

Mitral Transcatheter Edge-to-Edge Repair in a Challenging Anatomy With Deeply Implanted Self-Expanding Valve and Severe Mitral Annular Calcification: A Case Report.

Muhammad Saad, Raviteja Guddeti, Nadia El-Hangouche, Santiago Garcia

The Carl and Edyth Lindner Research Center at The Christ Hospital, Cincinnati, Ohio.

Case report

Key points

From the paper's conclusion
  • We describe the case of an 82-year-old woman with prior TAVR (29 mm EVOLUT FX+; Medtronic), P2 flail, and heavy circumferential MAC underwent M-TEER with the PASCAL Ace device (Edwards Lifesciences).

Abstract

Mitral transcatheter edge-to-edge repair (M-TEER) in the setting of prior transcatheter aortic valve replacement (TAVR) and severe mitral annular calcification (MAC) can pose procedural challenges. We describe the case of an 82-year-old woman with prior TAVR (29 mm EVOLUT FX+; Medtronic), P2 flail, and heavy circumferential MAC underwent M-TEER with the PASCAL Ace device (Edwards Lifesciences). This case illustrates that M-TEER can be performed safely and effectively in anatomies complicated by severe MAC and prior TAVR with careful preprocedural planning, intraprocedural imaging, and operator experience.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers