Evaluation of Deep and Dynamic Proteomic Screening Strategies at Sub-50 Hz Scan Speed and without Robotic Sample Preparation.
Bhavesh S Parmar, Yuanyuan Liu, Parviz Ghezellou, Christian Münch
Institute of Molecular Systems Medicine, Goethe University, Frankfurt am Main60528, Germany.
Key points
From the paper's conclusion- We find that the 96-well format STrap, in combination with C18 plates, provides the most robust throughput for a nonautomated sample preparation workflow.
Abstract
Advances in ultrafast mass analyzer technology and procedural automation have enabled proteomic screening at the throughput of hundreds of proteomes per day. However, these approaches often require expensive instrumentation upgrades and robotic automation that remain inaccessible to many research laboratories and core facilities. In this study, we address the feasibility of scaling up proteomic screening capabilities with minimal upgrade cost by focusing on (a) strategies for nonautomated high-throughput sample preparation from 96-well cell culture, (b) data acquisition on sub-50 Hz scan speed hybrid and tribrid Orbitrap instruments, and (c) data analysis strategies for label-free and labeled proteomic screening. We find that the 96-well format STrap, in combination with C18 plates, provides the most robust throughput for a nonautomated sample preparation workflow. Furthermore, we show that for static proteomes, an isobaric tandem mass tag (TMT)-based multiplexing approach provides deeper and more precise proteome coverage, whereas data-independent acquisition (DIA) is more accurate, albeit with a reduced dynamic range and more missing values. Finally, we extend the optimized workflow to proteome turnover studies using pulsed stable isotope labeling by amino acids in cell culture (pSILAC), highlighting the key advantages and trade-offs of DIA and TMT data-dependent acquisition strategies for capturing protein translation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance Characteristics of Zeno Trap Scanning DIA for Sensitive and Quantitative Proteomics at High ThroughputPROTEOMICS · 2025
- Benchmarking turboDDA for sensitive proteome and phosphoproteome analysis of trace samples: Application to single human oocytes.Talanta · 2026
- An Instrumental Optimization of a Label-Free Proteomic Method for Trace Protein Input.Analytical chemistry · 2026
- Rapid Eco-AI CE-MS Enables Sub-7 Min Low-Input Proteome Profiling with Quantitative Validation.Analytical chemistry · 2026
- Benchmarking informatics workflows for data-independent acquisition single-cell proteomicsNature Communications · 2025
- Higher-Throughput Proteome Profiling Enabled by Parallelized Pre-Accumulation and Optimized Ion Processing in the Orbitrap Astral Zoom Mass SpectrometerMolecular & Cellular Proteomics · 2026