Digital Twins to Mimic the Control Arm of a Neonatal Randomized Controlled Trial: A "Proof-of-Principle" Feasibility and Comparability Study.
Prakesh S Shah, Isabelle Marc, Mireille Guillot, Sophie von Teichman Logischen, Etienne Pronovost, Eugene W Yoon, Marc Beltempo, Mohan Pammi,
Department of Pediatrics, Mount Sinai Hospital, Toronto, M5G 1X5, Ontario, Canada. Electronic address: prakeshkumar.shah@sinaihealth.ca. · Department of Pediatrics, Centre Hospitalier Universitaire de Québec-Université Laval, 2705 Boulevard Laurier, G1V 4G2, Québec, Canada. Electronic address: Isabelle.Marc@crchudequebec.ulaval.ca.
Key points
From the paper's conclusion- This study demonstrated the feasibility of generating DTC for the control arm of a completed RCT. Further evaluations through a greater number of DTC per actual controls; other completed RCTs; and concurrent prospective identification of DTC are needed.
Abstract
OBJECTIVE: To assess the development, feasibility and comparability of an external digital twin control (DTC) arm that resembles the actual control arm of a completed trial utilizing the Canadian Neonatal Network (CNN) database. STUDY DESIGN: We used data from the control arm of a placebo-controlled trial, the MOBYDICK trial, which assessed maternal docosahexaenoic acid supplementation for bronchopulmonary dysplasia-free survival in breastfed infants of <29 weeks' gestation. We identified 1 and 2 DTC matches for each control arm patient of original trial using important inclusion criteria from the CNN database. We assessed feasibility and comparability by calculating standardized difference; the preservation of the correlation structure of groups by reporting element-wise mean absolute difference; and overall group similarity metric by calculating the mean Gower's distance. RESULTS: Among 255 actual control neonates, 1 DTC match was identified for all patients, and 2 matches were identified for 252 neonates. The baseline characteristics between 2 groups were similar except for a higher outborn rate and a lower rate of antenatal corticosteroid use in DTC. For outcomes, DTC were similar to actual controls except that DTC infants had higher rates of NEC. The element-wise mean absolute difference was <0.1 and Gower's distance was <0.3 which were within acceptable range. CONCLUSIONS: This study demonstrated the feasibility of generating DTC for the control arm of a completed RCT. Further evaluations through a greater number of DTC per actual controls; other completed RCTs; and concurrent prospective identification of DTC are needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A novel digital twin strategy to examine the implications of randomized clinical trials for real-world populationsnpj Digital Medicine · 2026
- The Role of Digital Twins in Clinical Trials: A New Perspective on Methodological and Statistical Challenges.Therapeutic innovation & regulatory science · 2026
- Using AI‐generated digital twins to boost clinical trial efficiency in Alzheimer's diseaseAlzheimer s & Dementia Translational Research & Clinical Interventions · 2025
- Digital twin-based simulation of physiological responses to prone positioning in mechanically ventilated ICU patients.Intensive care medicine experimental · 2026
- Enhancing randomized clinical trials with digital twinsnpj Systems Biology and Applications · 2025
- Digital Twins for Monitoring Neuromotor Development in Preterm Infants: Conceptual Framework and Proof-of-concept StudyJournal of Medical Systems · 2025