Journal of pharmaceutical and biomedical analysis

Untargeted urine UHPLC-HRMS analysis for diagnosing cancer and endocrine pathologies, with emphasis on data pre-processing.

Tatyana Malitskaya, Elina Gashimova, Azamat Temerdashev, Dmitry Perunov, Vladimir Porkhanov, Igor Polyakov, Sanka N Atapattu, Yu-Qi Feng

Kuban State University, Stavropol'skaya St. 149, Krasnodar 350040, Russia. · Kuban State University, Stavropol'skaya St. 149, Krasnodar 350040, Russia. Electronic address: elina.gashimova@yandex.ru.

Key points

From the paper's conclusion
  • Overall, this study demonstrates that pre-processing should be regarded as a critical analytical step, alongside instrumental optimization, to improve metabolome coverage, robustness, and the reliability of urinary biomarker panels for cancer diagnostics.

Abstract

Urine untargeted metabolomics offers considerable promise for cancer diagnostics, yet its clinical utility remains constrained by limited biomarker specificity and the lack of standardized pre-processing workflows. In this study, we developed an optimized UHPLC-HRMS workflow for urine analysis and systematically compared six pre-processing platforms; asari, IDSL.IPA, iMet-Q, MassCube, MS-DIAL, and tidymass, using a clinical cohort comprising 177 urine samples from cancer patients, healthy volunteers, and patients with endocrine pathologies. Instrumental optimization, including solid-phase extraction and chromatographic separation, enhanced the detection of low-abundance metabolites and enabled resolution of diagnostically relevant isobaric pairs such as testosterone/epitestosterone glucuronides and etiocholanolone/androsterone glucuronides. A key novelty of this work is the integrated evaluation of sample preparation, chromatographic performance, and multiple pre-processing strategies within a single clinical dataset, together with the use of endocrine pathologies as an additional control group to improve biomarker specificity. The pre-processing platforms showed marked differences in pre-processing time, detection, and biomarker selection, indicating that downstream diagnostic performance is strongly influenced by the chosen workflow. PLS-DA models based on the top metabolites putatively annotated by each platform yielded test accuracies ranging from 65.0% to 76.3%, with the highest test accuracy observed for MassCube. Overall, this study demonstrates that pre-processing should be regarded as a critical analytical step, alongside instrumental optimization, to improve metabolome coverage, robustness, and the reliability of urinary biomarker panels for cancer diagnostics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers