Optimisation of a dilute-and-shoot UHPLC-MS method for high-throughput urinary metabolomics.
Patricia Kelly, Caroline Kerbiriou, Bernadette White, Konstantinos Gkikas, Kelly Stewart, Gillian Farrell, Konstantinos Gerasimidis, Nicholas J W Rattray
School of Medicine, University of Glasgow, Glasgow, UK. · Strathclyde Institute of Pharmacy and Biomedical Sciences, 161 Cathedral Street, Glasgow, UK.
Key points
From the paper's conclusion- We compared three normalisation strategies for their effect on data precision: no normalisation, creatinine normalisation and probabilistic quotient normalisation (PQN).
Abstract
INTRODUCTION: Urinary metabolomics using liquid chromatography-mass spectrometry (LC-MS) holds great potential for biomarker discovery and clinical application. Large-scale studies and clinical trials require rapid, scalable methods. However, existing urine extraction and LC-MS approaches lack standardisation and clear recommendations for high-throughput use. OBJECTIVES: To optimise a dilute-and-shoot urinary metabolite extraction and untargeted ultra-high-performance LC-MS (UHPLC-MS) method suitable for large-scale studies, and to demonstrate its performance in a clinical cohort. METHODS: We systematically optimised eight parameters: extraction solvent, dilution factor, chromatographic gradient, injection volume, flow rate, gradient curve factor, full scan automatic gain control (AGC) and MS/MS AGC. Performance was assessed by the number of metabolites detected, peak quality, creatinine performance and peak quality factors (PQFs). The optimised method was applied to 1094 urine samples (862 clinical samples plus QCs) from healthy controls and patients with inflammatory bowel disease (IBD). We compared three normalisation strategies for their effect on data precision: no normalisation, creatinine normalisation and probabilistic quotient normalisation (PQN). RESULTS: The optimised method used a C18 column in positive ionisation mode. The mobile phases were water and acetonitrile, each with 0.1% formic acid (v/v). Data acquisition took 6.5 min, and the total run time was 10 min including a cleaning step. In the IBD cohort, over 1500 metabolites were putatively annotated in 182.3 h of instrument time. This saved over 91 h compared with the previously used method. CONCLUSIONS: This optimised method provides rapid, scalable untargeted urinary metabolomics suitable for large clinical studies and trials.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Untargeted urine UHPLC-HRMS analysis for diagnosing cancer and endocrine pathologies, with emphasis on data pre-processing.Journal of pharmaceutical and biomedical analysis · 2026
- MetaboRx: R Shiny application for quality assessment and preprocessing of mass spectrometry-based metabolomics data.bioRxiv : the preprint server for biology · 2026
- Normalization of GC-MS Metabolomics Data in Adherent Cells: A Practical Comparison of ApproachesInternational Journal of Molecular Sciences · 2026
- MRM Processor: An Integrated Workflow for Automated MRM Data Processing via Relative Retention Time Correction.Analytical chemistry · 2026
- MSlineaR: An R Package Assessing Linear Behavior to Improve Quality Assurance and Statistical Robustness in Untargeted Metabolomics.Analytical chemistry · 2026
- Comprehensive LC-MS Metabolomics Data Processing with notame R/Bioconductor Package.Methods in molecular biology (Clifton, N.J.) · 2026