LC-MS/MS method for quantification of dupilumab in human serum using Protein G enrichment.
Kun Yang, Jianhua Wu, Chengming Yang, Liang Liu
Department of Pharmacy, Zhongnan Hospital of Wuhan University, Wuhan 430071, China. · Department of Pharmacy, The First Affiliated Hospital of Yangtze University, Jingzhou, Hubei 434000, China.
Key points
From the paper's conclusion- Specifically, dupilumab was enriched from 50 µL serum using Protein G magnetic beads, followed by denaturation, reduction, alkylation, and tryptic digestion.
Abstract
Dupilumab, a monoclonal antibody targeting IL-4Rα, is used for the treatment of type 2 inflammatory diseases. Recent studies have revealed a nonlinear relationship between its serum concentration and clinical response, particularly a "biological tipping point" during dose interval prolongation, highlighting the need for individualized therapeutic drug monitoring (TDM). In this study, a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for dupilumab quantification in human serum was developed and validated. Specifically, dupilumab was enriched from 50 µL serum using Protein G magnetic beads, followed by denaturation, reduction, alkylation, and tryptic digestion. A surrogate peptide SGQSPQLLIYLGSNR was selected for quantification, and its stable isotope-labeled (SIL) analog served as an internal standard. Separation was performed on an Acquity UPLC BEH C8 column (50 mm × 2.1 mm, 1.7 µm) with detection using positive electrospray ionization in multiple reaction monitoring (MRM) mode. Excellent linearity was achieved from 1.00 to 400 µg/mL (r² > 0.99), with a lower limit of quantification of 1.00 µg/mL. Intra- and inter-run precision (%CV) and accuracy (%Bias) were within 9.27%. The validated method was successfully applied to analyze clinical serum samples. The established LC-MS/MS method provides a reliable alternative to immunoassays, with a wide dynamic range suitable for TDM and personalized dose interval adjustments in patients receiving dupilumab.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An automated column-switching LC-MS/MS method using immobilized trypsin for the rapid quantification of pembrolizumab in human serum.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Simultaneous Quantification of Vedolizumab, Ustekinumab, and Infliximab in Human Serum by LC-MS/MS: Application to Therapeutic Drug Monitoring in Inflammatory Bowel Disease.Drug design, development and therapy · 2026
- Multi-Attribute Methods for Biotherapeutics: A Decade of Evolution.Pharmaceuticals (Basel, Switzerland) · 2026
- Minimum Significant Ratio for Defining Treatment-Boosted ADA Responses Using Signal-to-Noise as an Alternative to Titer.The AAPS journal · 2026
- Towards new approach methodologies for biological therapeutics: a novel model-informed metric to assess immunogenicity riskFrontiers in Immunology · 2025
- Development and validation of qualitative methods for the detection of GLP-1 receptor agonists in serum and dried blood spots by LC-HRMS/MS for doping control purposes.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026