Preclinical evaluation of a fully threaded biodegradable magnesium alloy headless compression screw for enhanced fixation in small bones.
Hiroshi Noguchi, Kotaro Hanada, Ryunosuke Watanabe, Yasukazu Totoki, Yohei Tomaru, Akira Ikumi, Akira Kitagawa, Sakiko Orui,
Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Ibaraki, 305-8575, Japan. · Integrated Research Center for Advanced Manufacturing, National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki, 305-8564, Japan.
Key points
From the paper's conclusion- These findings indicate that the developed Mg alloy HC screw exhibits favorable mechanical performance, biocompatibility, and in vivo degradation. This study provides preclinical evidence supporting its potential clinical translation, particularly in eliminating the need for secondary implant removal surgery.
Abstract
BACKGROUND: Biodegradable magnesium (Mg) alloys have attracted attention as alternatives to conventional metallic implants; however, their clinical applicability to fully threaded headless compression (HC) screws has been scarcely investigated. METHODS: In this study, a fully threaded biodegradable Mg alloy HC screw was developed, and its mechanical performance, biological safety, and in vivo degradation behavior were systematically evaluated. Mechanical properties were assessed according to ASTM standards and compared with clinically used titanium (Ti) alloy and poly-L-lactic acid/hydroxyapatite (PLLA/HA) screws. Biological safety was evaluated in accordance with ISO 10993 and in compliance with Good Laboratory Practice. In vivo degradation behavior was investigated using a rabbit distal femoral condyle model. RESULTS: The Mg alloy HC screw demonstrated superior torsional strength compared with PLLA/HA screws and comparable insertion performance, along with enhanced fixation strength, compared with Ti alloy screws. No cytotoxicity, sensitization, or intracutaneous reactivity was observed. Although transient gas cavity formation was observed during the early implantation period, it progressively diminished over time and did not adversely affect bone formation or implant stability. CONCLUSION: These findings indicate that the developed Mg alloy HC screw exhibits favorable mechanical performance, biocompatibility, and in vivo degradation. This study provides preclinical evidence supporting its potential clinical translation, particularly in eliminating the need for secondary implant removal surgery. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: This article focuses on the preclinical evaluation of a fully threaded Mg-alloy HC screw developed to improve fixation performance for small bone fractures. The results of this study have significant clinical potential for the fully threaded design of biodegradable Mg alloy implants in fracture treatment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biodegradable Mg-Sr-Zr-Ho alloy with multifunctional angiogenic, antibacterial, anti-inflammatory, and osteogenic properties for orthopedic fixationChemical Engineering Journal · 2026
- Biodegradable Mg–Zn–Mn alloys for orbital bone fixation: Balancing corrosion resistance and mechanical integrityJournal of Materials Research and Technology · 2025
- A review of cytotoxicity testing methods and in vitro study of biodegradable Mg-1%Sn-2%HA composite by elution methodJournal of Materials Science Materials in Medicine · 2025
- One-year clinical outcomes after fixation of condylar head fractures using a reduced-head PEO-modified WE43 biodegradable magnesium screw.Frontiers in oral health · 2026
- In Vitro Degradation Behavior of the Mg-Cu Alloy in Simulated Gastric Fluid and Its Bioactivity against H. pylori and Gastric Cancer Cells.ACS biomaterials science & engineering · 2026
- Rare-earth-free magnesium-zinc alloy with controlled biodegradation and biocompatibility for novel biodegradable metallic stent.Biomaterials · 2026