Morphological analysis of the trapezium in Japanese patients with thumb carpometacarpal osteoarthritis for potential implantation of thumb carpometacarpal implants.
Shingo Komura, Hitoshi Hirose, Masanori Kito, Akihiro Hirakawa, Haruhiko Akiyama
Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan. Electronic address: komura.shingo.m7@f.gifu-u.ac.jp. · Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan.
Key points
From the paper's conclusion- Although simulated placement of a 9-mm cup was anatomically feasible in most Japanese patients, a subset of women had small trapezial dimensions or limited residual bone stock. These findings provide preliminary anatomical information that may be valuable for preoperative assessment and implant selection if thumb CMC total joint replacement becomes available in Japan in the future.
Abstract
BACKGROUND: Total joint replacement for thumb carpometacarpal (CMC) osteoarthritis requires sufficient trapezial bone stock for secure cup placement. Because trapezial dimensions may be smaller in Asian populations, the anatomical feasibility of currently available implants in Japanese patients remains uncertain. Although no thumb CMC prosthesis is currently approved in Japan, obtaining anatomical data relevant to cup implantation is important in anticipation of its potential future introduction. This study evaluated trapezial morphology and residual bone stock relevant to cup placement in Japanese patients with thumb CMC osteoarthritis. METHODS: This retrospective observational study included 100 joints in 86 patients with Eaton stage II or III osteoarthritis. Multiplanar reconstructed computed tomography images were used to establish a resection plane parallel to the scaphotrapezial joint surface at the most proximal level of the carpometacarpal articular surface of the trapezium. Radioulnar length (RUL), dorsopalmar width (DPW), and trapezial height (TH) were measured. Placement of a 9-mm diameter and 4.5-mm height cup was simulated, and cup overhang, scaphotrapezial joint perforation, and residual trapezial thickness beneath the cup (RTT) were assessed. RESULTS: Mean RUL, DPW, and TH were 19.1, 13.6, and 9.1 mm in men and 17.3, 12.3, and 7.9 mm in women, respectively. Cup overhang occurred in two of 76 female joints (2.6%), whereas no scaphotrapezial joint perforation occurred. Mean RTT was 4.6 mm in men and 3.4 mm in women. RTT ≤1 mm and ≤2 mm was observed in two (2.6%) and seven (9.2%) of female joints, respectively. CONCLUSIONS: Although simulated placement of a 9-mm cup was anatomically feasible in most Japanese patients, a subset of women had small trapezial dimensions or limited residual bone stock. These findings provide preliminary anatomical information that may be valuable for preoperative assessment and implant selection if thumb CMC total joint replacement becomes available in Japan in the future.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- TOUCH Tips: A New Paradigm for Thumb Carpometacarpal Osteoarthritis.Techniques in hand & upper extremity surgery · 2026
- Z-Deformity in Trapeziometacarpal Osteoarthritis: Outcomes of Pyrocardan® Arthroplasty and a Modified Extensor Pollicis Brevis Tenodesis Technique.Hand surgery & rehabilitation · 2026
- Trapezium-sparing distraction arthroplasty using the abductor pollicis longus tendon for advanced trapeziometacarpal osteoarthritis: A retrospective case series.Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association · 2026
- Biomechanical and Clinical Evaluation of Thumb Carpometacarpal Arthrodesis With Peritrapezial Release.The Journal of hand surgery · 2026
- Evaluation of Early Outcomes of Trapeziectomy With Suture-Button Suspensionplasty and Palmaris Longus Zig-Zag Augmentation for Thumb Carpometacarpal Osteoarthritis: A Prospective Case Series.Cureus · 2026
- Feasibility and accuracy of low-angle, non-orthogonal biplane fluoroscopic 2D-3D registration for dynamic analysis of the thumb carpometacarpal joint.Medical engineering & physics · 2026