Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association

Morphological analysis of the trapezium in Japanese patients with thumb carpometacarpal osteoarthritis for potential implantation of thumb carpometacarpal implants.

Shingo Komura, Hitoshi Hirose, Masanori Kito, Akihiro Hirakawa, Haruhiko Akiyama

Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan. Electronic address: komura.shingo.m7@f.gifu-u.ac.jp. · Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan.

Observational · n=86

Key points

From the paper's conclusion
  • Although simulated placement of a 9-mm cup was anatomically feasible in most Japanese patients, a subset of women had small trapezial dimensions or limited residual bone stock. These findings provide preliminary anatomical information that may be valuable for preoperative assessment and implant selection if thumb CMC total joint replacement becomes available in Japan in the future.

Abstract

BACKGROUND: Total joint replacement for thumb carpometacarpal (CMC) osteoarthritis requires sufficient trapezial bone stock for secure cup placement. Because trapezial dimensions may be smaller in Asian populations, the anatomical feasibility of currently available implants in Japanese patients remains uncertain. Although no thumb CMC prosthesis is currently approved in Japan, obtaining anatomical data relevant to cup implantation is important in anticipation of its potential future introduction. This study evaluated trapezial morphology and residual bone stock relevant to cup placement in Japanese patients with thumb CMC osteoarthritis. METHODS: This retrospective observational study included 100 joints in 86 patients with Eaton stage II or III osteoarthritis. Multiplanar reconstructed computed tomography images were used to establish a resection plane parallel to the scaphotrapezial joint surface at the most proximal level of the carpometacarpal articular surface of the trapezium. Radioulnar length (RUL), dorsopalmar width (DPW), and trapezial height (TH) were measured. Placement of a 9-mm diameter and 4.5-mm height cup was simulated, and cup overhang, scaphotrapezial joint perforation, and residual trapezial thickness beneath the cup (RTT) were assessed. RESULTS: Mean RUL, DPW, and TH were 19.1, 13.6, and 9.1 mm in men and 17.3, 12.3, and 7.9 mm in women, respectively. Cup overhang occurred in two of 76 female joints (2.6%), whereas no scaphotrapezial joint perforation occurred. Mean RTT was 4.6 mm in men and 3.4 mm in women. RTT ≤1 mm and ≤2 mm was observed in two (2.6%) and seven (9.2%) of female joints, respectively. CONCLUSIONS: Although simulated placement of a 9-mm cup was anatomically feasible in most Japanese patients, a subset of women had small trapezial dimensions or limited residual bone stock. These findings provide preliminary anatomical information that may be valuable for preoperative assessment and implant selection if thumb CMC total joint replacement becomes available in Japan in the future.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers