  • Thumb CMC fusion with bony peritrapezial release improves thumb motion compared to a traditional fusion in a biomechanical model. Patients undergoing thumb CMC fusion with a mixed ligamentous/bony peritrapezial release demonstrated encouraging early clinical results. The modified fusion has a nonunion rate within the range previously reported for conventional thumb CMC arthrodesis.

Abstract

PURPOSE: This study sought to evaluate the effect of peritrapezial release on outcomes following thumb carpometacarpal (CMC) arthrodesis. METHODS: For Part I (biomechanical), a replication cadaveric study was performed using a high-resolution motion capture system to track basilar thumb range of motion (ROM). Eleven specimens were evaluated, each in four conditions: intact, thumb CMC fusion, fusion with ligamentous peritrapezial release, and fusion with bony peritrapezial release. Thumb ROM was evaluated by calculating angular displacement and comparing nonplanar areas of motion of the thumb metacarpal. For Part II (clinical), a retrospective review was performed of 17 patients undergoing thumb CMC fusion with a mixed ligamentous/bony peritrapezial release. Patients completed the Visual Analog Scale (VAS); Disabilities of the Arm, Shoulder, and Hand (DASH); and Patient-Reported Wrist and Hand Evaluation (PRWHE) questionnaires pre- and postoperatively. Patients underwent ROM and strength testing, including power grip, key pinch, and tip pinch. Radiographs were obtained to evaluate for union. RESULTS: For Part I, thumbs with bony peritrapezial release had nearly 4× the motion compared to those with simulated fusion. For Part II, at an average follow-up of 78 weeks, grip strength increased 1.5× compared to preoperatively and key pinch strength improved 1.6×, both statistically significant. Tip pinch strength increased 1.3× but did not meet statistical significance. VAS scores decreased by 5.1 points, DASH scores improved by 31.5 points, and PRWHE scores improved by 39.9 points, all highly significant. Average Kapandji opposition score was 9.1. Average radial abduction was 35.1°, and average palmar abduction was 39.0°. One patient (5.9%) developed nonunion requiring revision. CONCLUSIONS: Thumb CMC fusion with bony peritrapezial release improves thumb motion compared to a traditional fusion in a biomechanical model. Patients undergoing thumb CMC fusion with a mixed ligamentous/bony peritrapezial release demonstrated encouraging early clinical results. The modified fusion has a nonunion rate within the range previously reported for conventional thumb CMC arthrodesis. CLINICAL RELEVANCE: Peritrapezial release addresses one of the principal historical concerns of thumb CMC arthrodesis, ie, stiffness. Thumb CMC fusion with peritrapezial release may warrant further consideration in older or lower-demand patients, not merely those considered "young" or "high-demand."

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers