Journal of stomatology, oral and maxillofacial surgery

Radiographic Bone Gain After Guided Bone Regeneration With a Porcine Cortical Membrane: A Retrospective Case Series.

Cyril Debortoli, Arthur Falguière, Romain Castro, Fabrice Campana, Charles Savoldelli, Jean-Hugues Catherine, Jean-Marc Foletti, Vincent Romao,

Oral and Maxillofacial Surgery Department, Institut Universitaire de la Face et du Cou, Centre Hospitalo-Universitaire de Nice, 06000 Nice, France. Electronic address: dr.debortolicyril@gmail.com. · Oral Surgery Department, Assistance Publique des Hôpitaux de Marseille, 264 Avenue Saint-Pierre, 13005 Marseille, France.

Case report · n=13

Key points

From the paper's conclusion
  • Among 15 evaluable sites, mean horizontal and vertical gains were 4.33 ± 1.55 mm (95% CI 3.47-5.19) and 4.11 ± 1.99 mm (95% CI 3.01-5.22), with the failed site imputed as zero (16 sites), 4.06 ± 1.84 and 3.85 ± 2.18 mm. CCCs were 0.994-0.998. One site failed after infection (augmentation success 15/16); membrane exposure occurred at 2/16 sites and refractory pain in 4/13 patients. All 27 implants placed in the 15 augmented sites were in function at one year; mean marginal bone loss was 0.41 mm.

Abstract

INTRODUCTION: Guided bone regeneration (GBR) is used to reconstruct alveolar defects before implant placement. Resorbable membranes provide limited space-maintaining rigidity, whereas non-resorbable devices are more rigid but may require removal and carry exposure risks. This retrospective case series describes GBR outcomes using a resorbable porcine cortical membrane in Cawood and Howell Class IV-VI defects. METHODS: Sixteen GBR procedures were performed in 13 patients. Site-level horizontal and vertical bone gain were measured by superimposition of pre-operative and six-month CBCT datasets; measurement agreement was assessed with Lin's concordance correlation coefficient (CCC) and Bland-Altman analysis. Complications, augmentation success, one-year implant survival and marginal bone loss were recorded. RESULTS: Among 15 evaluable sites, mean horizontal and vertical gains were 4.33 ± 1.55 mm (95% CI 3.47-5.19) and 4.11 ± 1.99 mm (95% CI 3.01-5.22), with the failed site imputed as zero (16 sites), 4.06 ± 1.84 and 3.85 ± 2.18 mm. CCCs were 0.994-0.998. One site failed after infection (augmentation success 15/16); membrane exposure occurred at 2/16 sites and refractory pain in 4/13 patients. All 27 implants placed in the 15 augmented sites were in function at one year; mean marginal bone loss was 0.41 mm. DISCUSSION: In this small uncontrolled series, GBR using a porcine cortical membrane with a mixed autogenous/bovine particulate graft was associated with approximately 4 mm horizontal and vertical bone gain. Because the procedure combines several components and seven sites overlap a previous report, these findings extend preliminary evidence and do not establish membrane-specific efficacy. Prospective comparative studies are required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers