Digital Volumetric Planning and Mixed Reality-Guided Anterolateral Thigh Flap Reconstruction for Maxillary Defects.
Hui Zhu, Wenbo Zhang, Shuo Liu, Xin Peng, Jiazeng Su, Yao Yu
Department of Oral and Maxillofacial Surgery Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology. · Department of Oral and Maxillofacial Surgery Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology. Electronic address: sujiazeng@163.com.
Key points
From the paper's conclusion- Digital volumetric planning combined with MR-guided ALTF harvest was technically feasible in this preliminary cohort and provided a reference for individualized flap design. The findings should be interpreted as exploratory, and comparative studies with larger samples are needed to determine whether this workflow improves clinical outcomes or reduces tissue trimming.
Abstract
BACKGROUND: Accurate restoration of soft-tissue volume remains challenging in maxillary reconstruction. This study assessed the feasibility of a defect-oriented digital volumetric planning workflow combined with mixed reality (MR)-guided anterolateral thigh flap (ALTF) harvest. METHODS: Patients who underwent maxillectomy followed by ALTF reconstruction between November 2023 and January 2025 were retrospectively reviewed. Preoperative CT data were imported into Mimics Medical 21.0 for three-dimensional reconstruction of the maxilla and tumor. Virtual osteotomy and defect simulation were performed to calculate the simulated recipient-defect capacity, designated as V1. Flap dimensions were then designed using V1 and donor-site adipose thickness. MR guidance was used intraoperatively for perforator localization and flap harvest. Intraoperative flap volume was measured by water displacement (V2), and postoperative flap volume was quantified on CT imaging (V3). Secondary outcomes included flap utilization rate, complications, speech intelligibility, patient satisfaction, and University of Washington Quality of Life scores.The three related volumes were compared using the Friedman test, followed by Bonferroni-adjusted pairwise comparisons. RESULTS: Fifteen patients were included. Mean flap thickness was 10.80 ± 3.49 mm. Median V1, V2, and V3 values were 61.57 mL (interquartile range [IQR], 44.53), 75.00 mL (IQR, 52.00), and 64.26 mL (IQR, 40.65), respectively. The overall difference was significant (Friedman statistic = 17.200, degrees of freedom = 2; P < 0.001). V2 was significantly greater than V1 (adjusted P < 0.001) and V3 (adjusted P = 0.003), whereas V1 and V3 did not differ significantly (adjusted P = 1.000). Mean flap utilization rate was 91.13 ± 9.67%. All flaps survived. One patient developed titanium mesh exposure after radiotherapy; no other major complications occurred. Postoperative speech intelligibility and quality-of-life outcomes were generally favorable. CONCLUSIONS: Digital volumetric planning combined with MR-guided ALTF harvest was technically feasible in this preliminary cohort and provided a reference for individualized flap design. The findings should be interpreted as exploratory, and comparative studies with larger samples are needed to determine whether this workflow improves clinical outcomes or reduces tissue trimming.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative evaluation of mixed reality, CTA-based digital guide, and hand-held Doppler for anterolateral thigh perforator localization in head and neck reconstruction.International journal of oral and maxillofacial surgery · 2026
- Postoperative volume loss of microvascular free flaps - a three-dimensional analysis.Oral and maxillofacial surgery · 2026
- Multi-planar reconstruction and 3D volume rendering as tools of anatomical dissection and morphometry on the example of cadaveric study of inferior medial genicular artery : Comparison of visualisation of branches of the inferior medial genicular artery using 3D volume reconstruction, MPR, and a fresh-frozen cadaver.Surgical and radiologic anatomy : SRA · 2026
- Innovative Digital Workflow Using Full-Arch Digital Implant Impression With Horizontal Scanbody: A Case Report.Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995) · 2026
- Virtual surgical planning-assisted versus free-hand head and neck reconstruction: Systematic review, meta-analysis, and a novel classification.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Low-Cost Digital Workflow for Preoperative Templating for Paramedian Forehead Flaps: A Preclinical Validation Study.The Journal of craniofacial surgery · 2026