Impact of different frequency of cord occlusion mimicking pushing effort on fetal pH variation: an experimental sheep model.
L-E Galan, L Ghesquière, Y Hamoud, D Sharma, C Le Ray, J De Jonckheere, C Garabedian
Univ. Lille, CHU Lille, ULR 2694 - METRICS - Evaluation des technologies de santé et des pratiques médicales, F-59000 Lille, France; CHU Lille, Department of Obstetrics, F-59000 Lille, France. Electronic address: louis-edouard.galan@chu-lille.fr. · Univ. Lille, CHU Lille, ULR 2694 - METRICS - Evaluation des technologies de santé et des pratiques médicales, F-59000 Lille, France; CHU Lille, Department of Obstetrics, F-59000 Lille, France.
Key points
From the paper's conclusion- In this experimental model, increased lactate levels and mean arterial pressure, indicative of fetal adaptation, were higher with more intensive occlusions.
Abstract
OBJECTIVE: To evaluate the effect of pushing effort frequency mimicked by cord occlusion on fetal hemodynamics and gasometry in a pregnant ewe model. STUDY DESIGN: Nine pregnant ewes were instrumented. Two patterns were compared: (1) an intensive occlusion group: 1 minute of conventional expulsive effort mimicked by cycles of 3 12-second complete cord occlusions interspersed with 12-second partial cord occlusions, with 2 minutes between each cycle; and (2) a moderate occlusion group: 1 minute of expulsive effort mimicked by 2 12-second complete cord occlusions, with 2 minutes between each cycle and no occlusions in 1 out of every 5 cycles. RESULTS: At 30 minutes, the lactate levels of the intensive occlusion group were higher than those of the moderate occlusion group (3.23 [2.42; 3.77] vs. 2.37 [1.77; 2.60] mmol/L, respectively; P<.05). At 60 minutes, the mean arterial pressure of the intensive occlusion group was higher than that of the moderate inclusion group (52 [45; 57] vs. 44 [41; 53] mmHg, respectively; P<.05). Other hemodynamic and gasometric measures did not differ between the two groups. CONCLUSIONS: In this experimental model, increased lactate levels and mean arterial pressure, indicative of fetal adaptation, were higher with more intensive occlusions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intrapartum Evaluation of the FetusCambridge University Press eBooks · 2026
- Multiparameter continuous fetal monitoring for early detection of physiologic derangement in a lamb model of fetal surgery.American journal of obstetrics & gynecology MFM · 2026
- Physiological Versus Directed Pushing During the Second Stage of Labor: A Non-Randomized Quasi-Experimental Study of Maternal Recovery and Clinical Outcomes.Healthcare (Basel, Switzerland) · 2026
- Implementation of physiological interpretation of fetal heart rate changes: from scientific principles to frontline practiceThe Journal of Maternal-Fetal & Neonatal Medicine · 2026
- Lactate in pregnancy and labor: current evidence and future perspectives for fetal surveillanceArchives of Gynecology and Obstetrics · 2026
- Mode‐specific fetal heart rate signal dropout as a marker of perinatal asphyxia: A multicenter observational study using causal machine learning methodsInternational Journal of Gynecology & Obstetrics · 2026