Multiparameter continuous fetal monitoring for early detection of physiologic derangement in a lamb model of fetal surgery.
Steven T Papastefan, Daniel R Liesman, Jianlin Zhou, Hedan Bai, Katherine C Ott, Catherine R Redden, Mingzheng Wu, Xavier F Pombar,
The Chicago Institute for Fetal Health, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL; Division of Pediatric Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL. · Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL; Department of Mechanical Engineering, Northwestern University, Evanston, IL.
Key points
From the paper's conclusion- In conclusion, profound fetal hypoxia, acidosis, and hypothermia occur frequently in the absence of fetal bradycardia. The novel multiparameter continuous probe detected FHR changes with minimal latency after clinically relevant fetal hypoxic stressors.
Abstract
BACKGROUND: Fetal echocardiography is the gold standard for intraoperative monitoring during fetal surgery but hinges on fetal bradycardia as the primary indicator for fetal distress. However, fetal bradycardia likely represents a terminal stage of physiologic decompensation when encountered in fetal surgery. OBJECTIVE: To evaluate the relationship between fetal heart rate changes and fetal physiologic derangement during stressors relevant to fetal surgery and to assess the potential contribution of continuous multiparameter fetal monitoring in the early detection of fetal distress. STUDY DESIGN: To challenge this hypothesis, we utilized a novel, integrated fetal monitoring probe to provide real-time core measurements of fetal oxygen saturation (SpO2), temperature, and FHR. Maternal (pre-placental) hypoxia, umbilical cord occlusion (post-placental hypoxia), and fetal hypothermia were induced to simulate clinically relevant perturbations in fetal surgery in a large animal model. RESULTS: Fetal bradycardia (defined as FHR<110) most often occurred in the setting of FPD, with positive-predictive value of 100% for fetal hypoxia, 83.3% for acidosis, and 91.7% for hypercarbia. However, the negative-predictive value of bradycardia was 41.5% for hypoxia, 62.5% for acidosis, 37.2% for hypercarbia, and 37.8% for acidosis. Time from the onset of FPD to detection of FHR changes was significantly longer than fetal SpO2 changes in the case of pre-placental hypoxia. Distinct patterns of fetal SpO2 and FHR changes were present between pre-placental hypoxia, post-placental hypoxia, and fetal hypothermia that were detectable via multiparameter fetal monitoring probe tracings. CONCLUSIONS: In conclusion, profound fetal hypoxia, acidosis, and hypothermia occur frequently in the absence of fetal bradycardia. The novel multiparameter continuous probe detected FHR changes with minimal latency after clinically relevant fetal hypoxic stressors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mode‐specific fetal heart rate signal dropout as a marker of perinatal asphyxia: A multicenter observational study using causal machine learning methodsInternational Journal of Gynecology & Obstetrics · 2026
- Simultaneous acquisition of maternal and dual-fetal electrocardiography with maternal haemodynamic monitoring in anaesthetized pregnant rats.Experimental physiology · 2026
- Intrapartum Evaluation of the FetusCambridge University Press eBooks · 2026
- Introducing the Moyo device for intrapartum fetal heart rate monitoring among women with high-risk pregnancies in a low-resource setting: a quasi-experimental study.BMJ open · 2026
- Cerebral hemodynamics and cytochrome c oxidase in hypoxic-ischemic rabbit fetusesbioRxiv · 2026
- Noninvasive assessment of fetal metabolic acidemia by automated analysis of cardiac function using color tissue Doppler imaging in a sheep model.Scientific reports · 2026