Environmental impact of urine analyses: Comparison of manual, semi and fully automated analytical workflows.
Julien Brunier, Clara Mourgues, Fanny Auger, Gérard Lina, François Vandenesch, Céline Ramanantsoa, Olivier Dauwalder
Centre Hospitalier Le Mans, Laboratoire de microbiologie, Le Mans, France. · Primum non nocere, Béziers, France.
Key points
From the paper's conclusion- The EI of UA depends on both the automation level and the organizational scale. While automation does not always reduce impacts linearly, full automation offers the best carbon and health performance in high-throughput settings. Integrating LCA into laboratory strategy may support the ecological transition of microbiology.
Abstract
OBJECTIVES: Urinary tract infection is the most common infection requiring urinalysis (UA). Due to economical constraints, many laboratories have merged to use full laboratory automation instruments for high volume of urine samples. However, the environmental impact (EI) of UA is still unknown, particularly according to automation levels. The present study aimed to document the environmental impact of UA for the first time. METHODS: We used the life cycle assessment (LCA) methodology (ISO 14040/44, 2006) to compare manual, semi-automated and fully-automated analytical workflows for Escherichia coli UA (ECUA) including cytology, isolation, and antibiotic susceptibility tests (AST). Using a multicenter approach, we measured midpoints and endpoints levels defined by the impact assessment method ReCiPe 2016. RESULTS: ECUA carbon footprint was 1.9, 2.6 and 1.1 kgCO2eq using manual, semi-automated and fully-automated workflows respectively. AST processes accounted for 66.8%, 79.0%, and 59.9% of emissions, respectively. The fully-automated workflow had the lowest impact for 12/18 midpoint indicators and had the lowest impact on human health (2.9 × 10-6 disability-adjusted life years (DALY) vs 3.7 × 10-6 for manual and 6.9 × 10-6 for semi-automated workflows). When scaled to 50,000 ECUA/year, the manual workflow had the lowest impact for 10/18 midpoints and human health (3.7 × 10-6 DALY), but its impact remained higher than fully-automated in real conditions. CONCLUSIONS: The EI of UA depends on both the automation level and the organizational scale. While automation does not always reduce impacts linearly, full automation offers the best carbon and health performance in high-throughput settings. Integrating LCA into laboratory strategy may support the ecological transition of microbiology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analytical Life Cycle Assessment as a 10-Stage Framework for Evaluating and Improving the Sustainability of Analytical Workflows.Analytical chemistry · 2026
- Automated on-site disinfection of urine collection bags: a sustainable waste managementEuropean Journal of Public Health · 2026
- Automated monitoring of urine output in hospitalized patients with indwelling urinary catheters: a clinical evaluation on the cardiology wardNetherlands Heart Journal · 2026
- From lifecycle assessment to decision support: An exploratory framework for environmental impact assessment of peritoneal dialysis systemsEnvironmental Impact Assessment Review · 2026
- A Streamlined Automated Liquid Handling and 96-Well Solid-Phase Extraction for Single Low-Volume Urine Aliquot Multiclass Biomarker Analysis in Human Biomonitoring.Environmental chemistry and ecotoxicology · 2026