Automated monitoring of urine output in hospitalized patients with indwelling urinary catheters: a clinical evaluation on the cardiology ward
Jos Perdeck, Gilmer A. Sussenbach, Elliot N. Bradshaw, Ingeborg K. Go, Reinoud E. Knops, Tom F. Brouwer
Amsterdam Neuroscience · Amsterdam UMC Location University of Amsterdam
Key points
From the paper's conclusion- This single-centre observational study enrolled 25 cardiology patients (519 h) with indwelling urine catheters.
Abstract
BACKGROUND: Urine output (UO) is a key clinical parameter for assessing hemodynamic status, yet manual UO measurements are labour-intensive, and documentation is often incomplete and error-prone. The Gravity of Flow study evaluated an in-house developed urine production gauge (UPG), designed as a reusable-cost system compatible with standard urine bags for automatic, continuous UO measurement and Electronic Health Record (EHR) integration. METHODS: This single-centre observational study enrolled 25 cardiology patients (519 h) with indwelling urine catheters. To assess completeness and volume accuracy, UPG performance was compared against standard manual urine charting and a 24-hour container (gold standard). RESULTS: The UPG achieved superior median completeness compared to manual charting (100% vs. 40%, p < 0.001). The device demonstrated high accuracy (median absolute percentage error 2.3%) and minimal bias (median -3 mL), meeting ±5% equivalence criteria (78.3% within bounds). In contrast, manual charting failed to meet equivalence. Performance of the UPG remained consistent across various UO flow rates. CONCLUSION: By providing superior, automated UO data (accuracy, completeness, reliability), the UPG has the potential to optimise fluid management, enable earlier intervention, and reduce nursing workload. Future research should validate these benefits across various clinical settings and over longer periods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Closing the documentation gap: accuracy and completeness of a novel EHR-integrated gravitational urine production gauge vs. manual chartingEuropean Heart Journal · 2026
- From manual to digital: prospective ICU evaluation of the FIZE kUO® for continuous urine output measurement.BMC nursing · 2026
- Comparison of an automated and paper bladder diary in pediatric patients: mixed-methods, randomized crossover study.Frontiers in pediatrics · 2026
- B-303 Evaluating an Automated Urinalysis System: Analytical Performance and Verification StrategiesClinical Chemistry · 2026
- Bladder scanning in children: accuracy of volume estimation and detection of urinary retentionmedRxiv · 2026
- Visualizing grades of hematuria for communication enhancement and continuous bladder irrigation guidance.Urology annals · 2026