Marginal fit, internal adaptation, and thermocycling effects on the mechanical and optical properties of graphene CAD-CAM and zirconia crowns for primary molars: An in-vitro study.
Keshav Rajesh, Jessy Paulraj, Subhabrata Maiti
Department of Pediatric and Preventive Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 77, India. · Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 77, India.
Key points
From the paper's conclusion- Under in vitro conditions, G-CAM crowns demonstrated superior marginal fit, internal adaptation, and fracture resistance compared with zirconia crowns. Thermocycling had minimal effect on surface and optical properties, though clinical studies are needed to confirm long-term performance.
Abstract
AIM: To evaluate the marginal fit and internal adaptation of graphene-reinforced CAD-CAM crowns compared with prefabricated zirconia crowns, and to assess the influence of thermocycling on their mechanical and optical properties. MATERIALS AND METHODS: In this in vitro comparative study, typodont mandibular second primary molars were prepared using a standardized protocol and allocated into two groups: graphene-reinforced CAD-CAM (G-CAM) crowns and prefabricated zirconia crowns. Marginal fit was assessed using a stereomicroscope at 40× magnification, and internal adaptation was evaluated using a silicone replica technique combined with three-dimensional digital analysis. For fracture resistance, crowns were tested under pre- and post-thermocycling conditions using a universal testing machine. Disc specimens were prepared separately for surface roughness, microhardness, and color stability; within each parameter, the same specimens were evaluated before and after thermocycling. Artificial aging was performed using 5000 thermocycles (5°C-55°C). Statistical analysis included Shapiro-Wilk and Levene's tests, independent and paired t-tests, and two-way ANOVA (P < 0.05). RESULTS: G-CAM crowns showed significantly lower marginal discrepancy and internal gap values than zirconia crowns (P ≤ 0.002). Fracture resistance was higher in G-CAM crowns before and after thermocycling, with a significant reduction observed in both groups (P < 0.05). Surface roughness, microhardness, and color stability were unaffected by thermocycling (P > 0.05), with ΔE values within clinically acceptable limits. CONCLUSION: Under in vitro conditions, G-CAM crowns demonstrated superior marginal fit, internal adaptation, and fracture resistance compared with zirconia crowns. Thermocycling had minimal effect on surface and optical properties, though clinical studies are needed to confirm long-term performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of Yttria Content and Margin Design on the Fracture Resistance of Monolithic Zirconia CrownsJournal of Functional Biomaterials · 2026
- Retention of graphene-reinforced polymethyl methacrylate crowns bonded to titanium-base abutments: an exploratory in vitro study.BDJ open · 2026
- Clinical Performance and Failure Mechanisms of Zirconia‐Based Toughened Ceramic CrownsInternational Journal of Applied Ceramic Technology · 2026
- Impact of Thermocycling and Artificial Aging on the Flexural Strength and Fracture Resistance of CAD/CAM Dental Ceramics: A Systematic Review and Meta-Analysis.Dentistry journal · 2026
- Comparison of Flexural Strength and Flexural Modulus of Conventional and Graphene-Reinforced Polymethyl-Methacrylate under Thermocycled and Non-Thermocycled Conditions: An in-Vitro Study.Pakistan journal of medical sciences · 2026
- Deep Margin Elevation With Various Resin Composites: Effect of Thermomechanical Aging on the Marginal Gap of CAD / CAM InlaysJournal of Esthetic and Restorative Dentistry · 2026