Functional Elbow Range of Motion During Activities of Daily Living: A Contemporary Assessment Using Wearable Inertial Motion Units.
Daniel Griffin, Nicole D Lee, Ruijie Yin, Dario Martelli, Aviram M Giladi, Michael W Kessler
Curtis National Hand Center, MedStar Union Memorial Hospital, Baltimore, MD; Department of Orthopaedic Surgery, MedStar Georgetown University Hospital. · Curtis National Hand Center, MedStar Union Memorial Hospital, Baltimore, MD; Georgetown University School of Medicine, Washington, DC.
Key points
From the paper's conclusion- Analysis of elbow kinematics with inertial motion capture yields similar flexion-extension arcs needed for hygiene tasks but a greater rotation arc than previously described with triaxial goniometer. Performing office tasks on a desk requires approximately 15° to 45° pronation.
Abstract
PURPOSE: In 1981, Morrey et al used a triaxial electrogoniometer affixed to the arm and forearm to demonstrate that 30° to 130° elbow flexion and rotation from 50° supination to 50° pronation are needed to perform most activities of daily living (ADLs). The present study seeks to address whether use of an inertial motion capture system to measure elbow joint angles during ADLs will result in different elbow range of motion than these historic measurements and to determine whether the elbow motion required for certain office tasks requires a different functional range of motion compared with previously tested ADLs. METHODS: Healthy volunteers enrolled at a single institution were fitted and calibrated with Xsens MVN motion capture system sensors so that real-time motion arcs could be captured. A series of movements related to hygiene, ADLs, and workplace tasks were performed. Joint angle data were aggregated to determine mean elbow flexion and pronosupination angles needed to complete each task. RESULTS: When assessed by inertial motion capture, most hygiene tasks could be achieved within the previously described flexion-extension arc; however, tasks performed at the center of the body (neck, chest, and sacrum) tended to be performed with greater supination than previously described. Most office tasks required more pronation than hygiene-related tasks. Using a computer mouse and reaching for a desk phone both required more elbow extension than what has previously been described as an acceptable range of motion. CONCLUSIONS: Analysis of elbow kinematics with inertial motion capture yields similar flexion-extension arcs needed for hygiene tasks but a greater rotation arc than previously described with triaxial goniometer. Performing office tasks on a desk requires approximately 15° to 45° pronation. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic V.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Using inertial measurement units to characterize musculoskeletal risk factors in a pilot study of a passive shoulder exoskeleton during a drilling-fastening task.Applied ergonomics · 2026
- Quantitative Assessment of Bilateral Upper-Limb Kinematics During Activities of Daily Living Using an Optoelectronic Motion-Capture System.Sensors (Basel, Switzerland) · 2026
- Effects of elbow angle and forearm rotation on elbow flexion torque and elbow-flexor surface electromyographic amplitudes.Frontiers in physiology · 2026
- Ergo-PAS: Validation of a smartphone-based real-time posture warning system for ergonomic risk intervention in construction work.Work (Reading, Mass.) · 2026
- A rigid-flexible coupled elbow rehabilitation monitoring system based on neural network fusionMeasurement Science and Technology · 2026
- Sensor-based assessment of ergonomic and kinematic implications of passive shoulder exoskeleton useThe International Journal of Advanced Manufacturing Technology · 2026