Hospital Water Safety and Nontuberculous Mycobacteria Risk: A National Evaluation of Organisational Readiness Across NHS Hospitals.
Niamh Reidy, Trupti Patel, Vanya Gant, Giovanni Satta
University College London Hospitals NHS Foundation Trust, Department of Infection, 250 Euston Road (5(th) floor Central Wing), London NW1 2PG. Electronic address: niamhreidy25@gmail.com. · University College London Hospitals NHS Foundation Trust, Department of Infection, 250 Euston Road (5(th) floor Central Wing), London NW1 2PG.
Key points
From the paper's conclusion- Design and control measures for waterborne pathogens varied considerably between organisations. Common themes included pipework reconfiguration and reduced use of tap water for patient care. Approaches to NTM testing and management were heterogeneous. Greater consensus on when environmental NTM testing informs management, and how results should guide action, could support organisational decision-making.
Abstract
OBJECTIVES: Following a Prevention of Future Deaths report highlighting risks from Mycobacterium abscessus in hospital water systems, NHS Estates Technical Bulletin (NETB) 2024/3 introduced updated measures to reduce risks from waterborne pathogens, including nontuberculous mycobacteria (NTM). This study described organisational responses and reported surveillance, design practices and water safety controls across NHS providers in England following publication of the bulletin. METHODS: A Freedom of Information Survey was sent to all NHS England organisations (n = 180). Questions explored awareness of NETB 2024/3; high-risk patient groups; water safety governance; NTM testing; control/remediation measures; and design activities. Structured data were collated, and free-text responses thematically analysed. RESULTS: The response rate was 90% (n=162). Awareness of NETB 2024/3 guidance was high (n=145, 90%), and almost all organisations had Water Safety Groups (99%). 71% reported caring for high-risk patient groups (n=115). Environmental NTM testing was undertaken by 14 Trusts (9%), six of these (42.9%) reported NTM detection, most often heater-cooler units and theatres. 13% (n=21) had Water Safety Plans specifically defining NTM risk mitigation. Testing strategies varied, from reactive sampling to scheduled programmes. Control measures for waterborne pathogens generally included temperature management (98%) and outlet descaling (94%); 70% (n=113) had undertaken design modifications in high-risk areas. CONCLUSIONS: Design and control measures for waterborne pathogens varied considerably between organisations. Common themes included pipework reconfiguration and reduced use of tap water for patient care. Approaches to NTM testing and management were heterogeneous. Greater consensus on when environmental NTM testing informs management, and how results should guide action, could support organisational decision-making.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of nontuberculous mycobacteria infection risks from CDC's water-related healthcare outbreak consultations, 2018-2024.Infection control and hospital epidemiology · 2026
- Waterborne outbreak of Mycobacterium abscessus in a UK specialist heart and lung hospital 2019-2026: patients, mitigations and implications.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2026
- Detection of non-tuberculous mycobacteria and other bacterial pathogens in dental unit waterlines, 2024, Germany: a microbiological single-centre studyPubMed · 2026
- Current infection control measures regarding Heater Cooler Units (HCU) in Germany after the mycobacteria chimaera outbreak 2014-2026.GMS hygiene and infection control · 2026
- Species Diversity of Nontuberculous Mycobacteria in Dental Unit Waterlines: Implications for Infection Control and Clinical Practice.Infection and drug resistance · 2026
- The burden of hospital-acquired legionellosis in German teaching hospitalsInfection · 2026