Measurement of salivary immunoglobulin G (IgG) from neonatal foals using enzyme-linked immunosorbent assay analysis does not correlate to plasma concentrations.
Deborah Mary Nash, Ahmed Jehanli, Monica Morganti, Petra Faltynkova, Rebecca Keating, Edward Matson, Joe Dunbar
Department of Life Sciences, Aberystwyth University, Penglais, Aberystwyth, SY23 3DA, UK. Electronic address: dmn@aber.ac.uk. · SOMA Bioscience Limited, Innovation Centre, Howbery Park, Wallingford, Oxfordshire, OX10 8BA, UK.
Key points
From the paper's conclusion- There was no correlation between blood and saliva IgG concentrations (mean 14.34g/L versus 0.24g/L respectively; P > 0.05).
Abstract
Measurement of neonatal immunoglobulin G (IgG), 24-48h post-partum, facilitates diagnosis of partial or failure of passive transfer of colostrum antibodies, indicating intervention to aid foal survival. Current methods for measuring IgG require invasive blood sampling. Sampling salivary IgG would enable rapid, point-of-care IgG detection by lay-people and veterinary cost savings. The study assessed a laboratory-based ELISA in detecting salivary IgG concentrations from neonates, to inform further development towards a stable-side test. Blood sampling was conducted routinely for IgG measurement as part of each foal's care at a commercial stud farm and data made available to this study. Simultaneous saliva samples were collected from foals (n=69). Blood and salivary IgG concentrations were compared by Pearson correlation coefficient. There was no correlation between blood and saliva IgG concentrations (mean 14.34g/L versus 0.24g/L respectively; P > 0.05). Results do not support development of saliva-based ELISA for IgG detection as a stable-side assessment tool.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of a quantitative immunochromatographic field test for measuring IgG in calf blood.The Veterinary record · 2026
- Evaluation of direct and indirect methods for assessing passive immunity in dairy and beef-cross calves initially fed colostrum replacer: a single-farm diagnostic accuracy studyFrontiers in Veterinary Science · 2026
- Evaluation of two commercial agarose gel kits for estimating IgG concentrations in neonatal calves: A pilot study.Polish journal of veterinary sciences · 2026
- Failure of Passive Transfer in neonatal foals - a review.Veterinary journal (London, England : 1997) · 2026
- Influence of sow, farrowing, and environmental factors on colostrum immunoglobulin G concentration in free-farrowing sows.Theriogenology · 2026
- Evaluation of a lateral flow immunoassay for the quantitative measurement of immunoglobulin G in foals compared with radial immunodiffusion.Journal of veterinary internal medicine · 2026