Validation of a quantitative immunochromatographic field test for measuring IgG in calf blood.
Nick Britten, Maggie A Fisher, Caroline A Fenn, Brian Middleton, Alastair Hayton, Joseph Payne, Chris Hudson, Rachel Hayton
Synergy Farm Health Limited, Maiden Newton, UK. · Ridgeway Research, St Briavels, UK.
Key points
From the paper's conclusion- The field test showed consistently strong agreement with the ELISA test across ages of calves and IgG values. Sensitivity and specificity in detecting FTPI were very good.
Abstract
BACKGROUND: Identifying failed transfer of passive immunity (FTPI) through the IgG status of calves is important for health and production. Rapid and accurate assessment of IgG status is desirable, but currently available methods have limitations. This study compares the performance of a novel immunochromatographic field test for IgG with a laboratory analysis for calves aged 1‒28 days using heparinised whole blood. METHODS: Excess blood collected from calves aged 1‒28 days on dairy farms in south-west England was used to compare the novel immunochromatographic field test with a commercially available ELISA. Bland‒Altman analysis, Pearson's correlation coefficient and receiver operating characteristic curves were used to evaluate agreement between the two tests. RESULTS: Pearson's correlation between the two tests was 0.78, showing a strong relationship. The ELISA returned slightly higher IgG concentrations than the field test, but the relationship was proportionally consistent across the range of values. The field test had a sensitivity and specificity of 86.7% and 95.6%, respectively, for the detection of FTPI at a threshold of 9.3 mg/mL. Test performance was consistent across the range of calf ages. LIMITATIONS: There was no systematic selection of calves. Sex, breed, farm and other variables were not available for analysis. Jugular samples were used rather than the recommended nose-prick samples. CONCLUSION: The field test showed consistently strong agreement with the ELISA test across ages of calves and IgG values. Sensitivity and specificity in detecting FTPI were very good.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of a lateral flow immunoassay for the quantitative measurement of immunoglobulin G in foals compared with radial immunodiffusion.Journal of veterinary internal medicine · 2026
- Measurement of salivary immunoglobulin G (IgG) from neonatal foals using enzyme-linked immunosorbent assay analysis does not correlate to plasma concentrations.Journal of equine veterinary science · 2026
- Evaluation of direct and indirect methods for assessing passive immunity in dairy and beef-cross calves initially fed colostrum replacer: a single-farm diagnostic accuracy studyFrontiers in Veterinary Science · 2026
- Evaluation of two commercial agarose gel kits for estimating IgG concentrations in neonatal calves: A pilot study.Polish journal of veterinary sciences · 2026
- Exploratory Evaluation of Refractometric, Biochemical, and Body Weight Change Parameters for Diagnosing Failure of Passive Transfer in Puppies.Veterinary sciences · 2026
- Validation of a New Quick and High-Throughput Latex Agglutination Immuno-Assay for Feline Alpha-1-Acid Glycoprotein.Veterinary clinical pathology · 2026