Journal of dentistry

Clinical performance of additively manufactured interim complete-arch dental prostheses for immediate implant loading: A retrospective observational study.

Federico Tirone, Erik Rolando, Donata Rodi, Laura Pozzatti, Stefano Salzano

Clinica Odontoiatrica Salzano Tirone, Cuneo, Italy. Electronic address: federico.tirone@gmail.com. · Laboratorio Odontoprotesico Rolando Cerato, Cuneo, Italy.

Observational · n=63

Key points

From the paper's conclusion
  • Additively manufactured resin interim IFCDPs showed a relevant prosthesis-level fracture proportion (19.5%) with frequent recurrence after reprinting, despite high early implant survival. Male sex was associated with a higher fracture rate, although this finding should be interpreted as exploratory. Fractured designs should be structurally reassessed before remanufacturing. Controlled prospective studies are required to validate design and manufacturing parameters.

Abstract

OBJECTIVES: To evaluate framework fracture and early implant survival of immediately loaded implant-supported fixed complete dental prostheses (IFCDPs) fabricated from additively manufactured interim resin using a novel integrated digital prosthetic protocol. METHODS: This retrospective multicenter observational study included 63 consecutive patients (77 arches) treated at four clinical centers. Overall, 320 implants were placed and immediately loaded. The primary outcome was the prosthesis-level framework fracture proportion during the interim-prosthesis observation period. Secondary outcomes were prosthetic screw loosening during the same period and implant failure, which was assessed over a 6-month retrospective follow-up. Generalized estimating equation (GEE) models were used to evaluate associations between framework fracture and patient/prosthetic variables while accounting for clustering of arches within patients. A multinomial logistic regression model was used to explore the association between implant failure and mechanical complications, and the Mann-Whitney U test was used to compare the number of fractures between arch types (α = 0.05). RESULTS: Fifteen of 77 IFCDPs experienced at least one framework fracture (19.5%). Overall, 33 fracture events occurred, including recurrent fractures in 13 arches after replacement prostheses were reprinted from the original files. Male sex was associated with a higher fracture rate than female sex in the arch-level GEE clustered by patient analysis (37.5% vs 9.7%; RR = 3.71; 95% CI, 1.01-13.60; p = 0.048). Five screw-loosening events occurred in 4 IFCDPs (5.2%). Three of 320 implants failed, yielding an early implant survival rate of 99.06%. Mechanical complications were not significantly associated with implant loss (p = 0.101). CONCLUSIONS: Additively manufactured resin interim IFCDPs showed a relevant prosthesis-level fracture proportion (19.5%) with frequent recurrence after reprinting, despite high early implant survival. Male sex was associated with a higher fracture rate, although this finding should be interpreted as exploratory. Fractured designs should be structurally reassessed before remanufacturing. Controlled prospective studies are required to validate design and manufacturing parameters. CLINICAL SIGNIFICANCE STATEMENT: Additively manufactured interim resin prostheses allow for a fully digital provisionalization with favorable early implant survival. However, the observed fracture proportion and frequent recurrence after reprinting indicate that mechanical reliability remains a relevant limitation. Careful structural planning, design reassessment after fracture, and close clinical monitoring are therefore required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers