Journal of dentistry

Contact and penetration patterns in digital jaw-motion workflows:a within-case comparison.

József Prugberger, Patrik Sashegyi, Judit Borbély, Kinga Turzó, Ákos Nagy, Gyula Marada, Attila Mühl

Private dental office, Vörösmarty Str.3., H-9700, Hungary. · Dental School, Medical Faculty, University of Pécs, Tüzér. Str. 1., H-7623 Pécs, Hungary.

Key points

From the paper's conclusion
  • AI-JM showed a smaller combined contact/penetration footprint than the tested comparators under the study conditions. IOS-AV comparisons reflect differences in both initial alignment and movement simulation; AX and AI-JM shared identical AI-derived alignment. Findings concern geometric compatibility with recorded morphology, not independently validated patient-specific movement accuracy.

Abstract

BACKGROUND: In fully digital workflows for monolithic restorations, virtual articulation combines interarch alignment with simulated movement. Wear-facet-informed AI estimates movement paths from intraoral scan morphology. This exploratory within-case study compared three workflows' software-rendered contact/penetration footprints using Contact Area Fraction (CAF). METHODS: Fourteen paired intraoral scan datasets underwent exocad processing using IOS-derived maximal intercuspal position (MIP) with average-value virtual articulation (IOS-AV; a common chairside digital reference), AI-derived MIP with axiography-programmed virtual articulation (AX), and the same AI-derived MIP with AI jaw-motion file-driven simulation (AI-JM). A pre-specified Python pipeline quantified CAF (%) as the proportion of red plus magenta pixels within the mapped region of exported color-coded 3D proximity/contact PDFs. Paired within-case comparisons used Friedman and post-hoc Wilcoxon signed-rank tests with Holm correction. RESULTS: CAF differed significantly among workflows (Friedman χ²(2)=13.86, p=0.001; Kendall's W=0.495). Median (IQR) CAF was 2.19% (1.59-3.67) for AI-JM, 3.01% (2.40-4.20) for AX, and 3.56% (2.57-4.50) for IOS-AV. AI-JM yielded the lowest CAF in 12/14 cases and significantly lower CAF than AX and IOS-AV (both Holm-adjusted p=0.04); AX and IOS-AV did not differ significantly. CONCLUSIONS: AI-JM showed a smaller combined contact/penetration footprint than the tested comparators under the study conditions. IOS-AV comparisons reflect differences in both initial alignment and movement simulation; AX and AI-JM shared identical AI-derived alignment. Findings concern geometric compatibility with recorded morphology, not independently validated patient-specific movement accuracy. CLINICAL SIGNIFICANCE: The smaller software-rendered contact/penetration footprint highlights AI-JM's potential to complement virtual occlusal assessment when planning monolithic restorations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers