Preparation design and connector geometry influence the mechanical behavior of additively manufactured periodontal splints.
Ines Bitri, Karim Nasr, Frédéric Vaysse, Xavier Dusseau, Luc Raynaldy, Sara Laurencin-Dalicieux, Thibault Canceill, Charlotte Thomas
Odontology Department, Health Faculty, Toulouse University, 3 Chemin des Maraîchers, Cedex 9, 31062 Toulouse, France.; Odontology Department, Toulouse University Hospital, 3 Chemin des Maraîchers, Cedex 9, 31062 Toulouse, France. · Odontology Department, Health Faculty, Toulouse University, 3 Chemin des Maraîchers, Cedex 9, 31062 Toulouse, France.; Odontology Department, Toulouse University Hospital, 3 Chemin des Maraîchers, Cedex 9, 31062 Toulouse, France.; Competence and Reference Center for Rare Oral Diseases (CCMR O-Rare), CHU Toulouse, 31062 Toulouse.
Key points
From the paper's conclusion- Preparation design was a stronger determinant of mechanical behavior than connector dimension alone. CFL combined with connector areas ≥6 mm² was associated with improved performance, though these preliminary findings require validation in more clinically representative models.
Abstract
UNLABELLED: Structural design guidelines for additively manufactured periodontal splints remain poorly defined, particularly regarding relative influence of preparation and connector geometry. OBJECTIVE: This in vitro study evaluated the effect of tooth preparation design and connector cross-sectional geometry on the mechanical behavior of these splints, providing preliminary mechanical insights rather than clinical design recommendations. MATERIAL AND METHODS: Standardized specimens were fabricated from a mandibular digital model, combining three preparation designs (no preparation, enamel chamfer finishing line [CFL], and CFL with proximal boxes) with three connector cross-sectional areas (5, 6, and 7 mm²) (n=10 per group; N=90). Specimens were printed by stereolithography using a permanent crown resin and tested under three-point bending (crosshead speed, 1 mm/min). Nominal flexural strength, deformation angle before fracture, and fracture pattern were recorded and analyzed using ANOVA with Bonferroni post hoc tests. RESULTS: Preparation design significantly influenced nominal flexural strength (p<.001). CFL alone showed the highest flexural strength (65.79 ± 20.98 MPa), significantly greater than no-preparation (27.36 ± 9.51 MPa) and CFL-with-proximal-boxes (29.64 ± 12.20 MPa). Increasing connector area improved performance only within the CFL group, with no difference between 6 and 7 mm² (73.75 ± 13.82 MPa vs. 81.45 ± 10.04 MPa; p>.99). Deformation capacity followed a similar pattern, and fracture mode was primarily determined by preparation design (p<.0001). CONCLUSIONS: Preparation design was a stronger determinant of mechanical behavior than connector dimension alone. CFL combined with connector areas ≥6 mm² was associated with improved performance, though these preliminary findings require validation in more clinically representative models. CLINICAL SIGNIFICANCE: Tooth preparation design, particularly a limited enamel chamfer finishing line, combined with connector cross-sectional areas ≥6 mm², was associated with improved mechanical performance under the present experimental conditions. These findings provide preliminary structural design insights for additively manufactured periodontal splints and warrant further validation in clinically representative models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Print Orientation and Post-Curing Duration on the Flexural Strength, Flexural Modulus and Vickers Microhardness of a 3D-Printed Occlusal Splint ResinBioengineering · 2025
- Effect of Connector Cross-Sectional Geometry on Fracture Resistance of Three-Unit Monolithic Zirconia Fixed Dental Prostheses Under Vertical and Oblique Loading: An In Vitro Study.Cureus · 2026
- The effect of build angle and intraarch connector design on the accuracy and fit of additively manufactured complete-arch implant-supported interim fixed prostheses.Journal of dentistry · 2026
- Effect of different splinting configurations on the accuracy of complete-arch digital implant impressions: An in vitro study.Journal of clinical and experimental dentistry · 2026
- Effect of Connection Geometry and Cantilever Length on the Mechanical Behavior of Ti6Al4V and PEEK Bar-Supported Implant Prostheses with Angled Abutments.Journal of functional biomaterials · 2026
- Connector Design and Pontic Span Length as Determinants of Mechanical Performance in Zirconia Fixed Dental Prostheses: A Systematic Review.Dentistry journal · 2026