Journal of dentistry

Influence of printing orientation, material-printer-workflow system, and glazing on the surface roughness and color stability of 3D-printed resins for permanent crowns.

Raiwint Khunwisetkul, Dusit Nantanapiboon, Soranun Chantarangsu, Atthasit Kanwiwatthanakun, Phasawat Chaiwutthinan, Murali Srinivasan, Wisarut Prawatvatchara

Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand. · Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand; Clinic of General-, Special Care-, and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.

Key points

From the paper's conclusion
  • Roughness differed among material-printer-workflow systems, with orientation effects in selected groups. Glazing improved aging-related surface and color stability under the tested conditions. The highest post-aging mean Ra remained below 0.2 µm, but glazed mean ΔE00 values (2.03-2.38) exceeded the acceptability threshold of 1.8.

Abstract

AIM: To evaluate the effects of printing orientation, material-printer-workflow system, and glazing on the surface roughness and color stability of permanent 3D-printed crown resins. MATERIALS AND METHODS: A total of 180 specimens were fabricated using three material-printer-workflow systems (VS, VarseoSmile Crown Plus; SA, Saremco Print Crowntec; CC, Ceramic Crown, SprintRay) with three printing orientations (0°, 45°, and 90°), and two surface conditions (glazed and non-glazed). Specimens were printed, finished, polished, treated (glazed/non-glazed), and subjected to 300 h of artificial accelerated aging. Surface roughness and color stability were measured by atomic force microscopy and spectrophotometry, respectively. Statistical analyses included ANCOVA, ANOVA, and post hoc Bonferroni tests (α = 0.05). RESULTS: Before aging, surface roughness differed among the non-glazed systems at all orientations (all P < 0.05), whereas printing orientation affected only non-glazed SA (P = 0.024). Glazing reduced surface roughness and color change in all material-printer-workflow systems. After aging, printing orientation affected surface roughness in non-glazed SA and CC (both P < 0.001) and glazed VS (P < 0.001), but not color change (all P ≥ 0.05). CC consistently exhibited the highest post-aging surface roughness. CONCLUSIONS: Roughness differed among material-printer-workflow systems, with orientation effects in selected groups. Glazing improved aging-related surface and color stability under the tested conditions. The highest post-aging mean Ra remained below 0.2 µm, but glazed mean ΔE00 values (2.03-2.38) exceeded the acceptability threshold of 1.8. CLINICAL SIGNIFICANCE: The findings inform the selection of material-printer-workflow systems and glazing protocols for 3D-printed restorations. Glazing improved aging-related surface and color stability under the tested laboratory conditions. Post-aging mean Ra remained below the cited 0.2-µm plaque-retention threshold, but glazed mean ΔE00 values were above the acceptability threshold of 1.8.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers