Clinical oral investigations

Influence of post-curing duration on degree of conversion, microhardness, and surface roughness of three commercially available 3D-printed permanent crown resins.

Dalndushe Abdulai, Rafat Sasany, Mutlu Özcan

Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey. · Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey. sasanyr@gmail.com.

Key points

From the paper's conclusion
  • Post-curing duration significantly increased the degree of conversion and Vickers microhardness of permanent 3D-printed crown resins in a material-dependent manner. Surface roughness remained comparable after standardized polishing. These findings suggest that post-curing protocols should be optimized according to the specific resin system rather than uniformly applied.

Abstract

OBJECTIVE: This in vitro study evaluated the influence of post-curing duration on the surface roughness (Ra), Vickers hardness (VHN), and degree of conversion (DC) of three commercially available permanent 3D-printed crown resins. MATERIALS AND METHODS: Three commercially available AM crown resins Saremco Print CROWNTEC (S), VarseoSmile TriniQ (B), and Permanent Crown Resin (F) were evaluated. A total of 180 disc-shaped specimens were fabricated and allocated into three material groups (n = 60), each subdivided into three post-curing durations (5, 30, and 60 min; n = 20). Ninety specimens were used for VHN and DC measurements, while an additional 90 specimens were used for Ra analysis. Surface roughness, microhardness, and degree of conversion were assessed using a profilometer, microhardness tester, and Fourier transform infrared spectroscopy, respectively. Data were analyzed using two-way ANOVA and Tukey's HSD test (α = 0.05). RESULTS: Surface roughness was not significantly affected by material type or post-curing duration (p > 0.05). In contrast, VHN and DC were significantly influenced by material type, post-curing duration, and their interaction (p < 0.001). Increasing post-curing time resulted in significant improvements in VHN and DC across all materials, with the greatest increase observed in the S group. The S groups exhibited the greatest increase in both VHN and DC with prolonged post-curing, whereas the B groups demonstrated a more limited response. CONCLUSIONS: Post-curing duration significantly increased the degree of conversion and Vickers microhardness of permanent 3D-printed crown resins in a material-dependent manner. Surface roughness remained comparable after standardized polishing. These findings suggest that post-curing protocols should be optimized according to the specific resin system rather than uniformly applied. CLINICAL RELEVANCE: Optimizing post-curing duration may improve the degree of conversion and surface hardness of permanent 3D-printed crown resins; however, further studies are required to confirm long-term clinical performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers