Operational harmonisation of SARS-CoV-2 RT-qPCR quantification across heterogeneous laboratory systems using WHO International Standard-traceable units.
Rie Moriuchi, Miyuki Nagano, So Fujiyoshi, Jun Suzuki, Yoshiyuki Sugishita, Yoshikazu Ishii, Fumito Maruyama
Microbial Genomics and Ecology Laboratory, The IDEC Institute, Hiroshima University, 1-3-1 Kagamiyama, Higashihiroshima, Hiroshima 739-8530, Japan; Quality Control Section, Tokyo Metropolitan Institute of Public Health, 3-24-1 Hyakunin-cho, Shinjuku-ku, Tokyo 169-0073, Japan. Electronic address: Rie_Moriuchi@member.metro.tokyo.jp. · Quality Control Section, Tokyo Metropolitan Institute of Public Health, 3-24-1 Hyakunin-cho, Shinjuku-ku, Tokyo 169-0073, Japan. Electronic address: Miyuki_1_Nagano@member.metro.tokyo.jp.
Key points
From the paper's conclusion- WHO IS-traceable calibration was operationally feasible within the evaluated EQA framework and markedly reduced statistically significant pairwise differences among reference RT-qPCR systems. In the real-world EQA, converted IS-traceable units provided a common quantitative scale across heterogeneous testing workflows.
Abstract
BACKGROUND: Quantitative reverse transcription PCR (RT-qPCR) is widely used for SARS-CoV-2 testing; however, quantification cycle (Cq) values are not standardised and cannot be directly compared across platforms. The World Health Organization (WHO) International Standard (IS) allows results to be expressed in IU/mL, although implementation in routine laboratory networks remains insufficiently evaluated. We evaluated whether WHO IS-traceable calibration can operationally harmonise RT-qPCR results across heterogeneous routine laboratory workflows within an external quality assessment (EQA) framework. METHODS: The study comprised a reference-system evaluation and a real-world EQA implementation. Eight representative RT-qPCR systems were evaluated at reference laboratories. The EQA included 33 datasets from 22 participating laboratories. Cq values were converted to copies/mL using system-specific calibration curves and then to IU/mL based on the dPCR-measured copy concentration and its WHO-assigned IU/mL value. Inter-system comparisons were performed using non-parametric methods. RESULTS: Across the eight reference systems, 13 of 28 pairwise comparisons showed significant Cq differences for each sample (p < 0.01). After conversion to IU/mL, no significant pairwise differences remained for Samples 1 and 2, and only one comparison remained significant for Sample 3. In the EQA, reported Cq values spanned 21.4-32.6, whereas corresponding IS values spanned 6.10-6.71 log10 IU/mL and clustered around the target concentration. CONCLUSIONS: WHO IS-traceable calibration was operationally feasible within the evaluated EQA framework and markedly reduced statistically significant pairwise differences among reference RT-qPCR systems. In the real-world EQA, converted IS-traceable units provided a common quantitative scale across heterogeneous testing workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Within- and Between-Operator Variability in Real-Time PCR-Based Human DNA Quantification and the Effect of Applying Calibration Curves Generated in Different Runs: A Preliminary Single-System StudyForensic Sciences · 2026
- Harmonization of Real-World Data for Vaccine-Preventable Infectious Diseases: Integration of SARS-CoV-2 Diagnostic and Serologic Data From Multiple Sources.Open forum infectious diseases · 2026
- Evaluating the use of the first WHO International Standard for anti-SARS-CoV-2 immunoglobulin to harmonise the readouts between commercial SARS-CoV-2 binding antibody tests: the HARMONY multicentre calibration studyThe Lancet Microbe · 2026
- SARS-CoV-2 and RSV external quality assessment on molecular detection and variant typing in European expert laboratories in 2025.Journal of clinical microbiology · 2026
- Real-Time Reverse Transcription Quantitative PCR (RT-qPCR) Methodological Standards and Reporting PracticesClinical Chemistry · 2025
- Analytical Agreement of the GeneXpert HIV-1 Viral Load Assay Compared with the Abbott Alinity m HIV-1 Assay.Diagnostics (Basel, Switzerland) · 2026