1-Year Safety and Effectiveness of a Next-Generation Dual-Seal Left Atrial Appendage Occluder.
Dhanunjaya Lakkireddy, Akash Makkar, Mohamad Alkhouli, Xavier Freixa, George Manoukian, Himanshu Agarwal, Hussam Abuissa, Khaled Awad,
Kansas City Heart Rhythm Institute and Research Foundation, Overland Park, Kansas, USA. Electronic address: dhanunjaya.lakkireddy@hcahealthcare.com. · Arizona Heart Arrhythmia Associates, Phoenix, Arizona, USA.
Key points
From the paper's conclusion- The VERITAS study results support the 1-year safety and effectiveness of the next-generation device. (Abbott Medical-VERITAS Study; NCT06707688).
Abstract
BACKGROUND: Left atrial appendage occlusion (LAAO) is a stroke prevention alternative for patients with atrial fibrillation (AF) intolerant to long-term oral anticoagulation (OAC). The next-generation dual-seal device was designed to improve operator ease of use while maintaining effective LAAO of the predicate device. OBJECTIVES: The purpose of this analysis was to evaluate the safety and effectiveness of a next-generation device through 1 year. METHODS: VERITAS is a single-arm, prospective, global, multicenter study. Patients with nonvalvular AF with an increased thromboembolism risk seeking a nonpharmacologic alternative to OAC were enrolled. One-year descriptive endpoints are provided, including mortality, neurological events, major bleeding, and device-related complications. One-year cardiac imaging was assessed for peridevice leak and device-related thrombus (DRT). RESULTS: Complete left atrial appendage (LAA) closure (0 mm leak) was observed in 91.1% (95% CI: 87.9%-93.7%) of patients by either transesophageal echocardiography (TEE) or cardiac computed tomography and 96.3% (95% CI: 93.2%-98.2%) by TEE alone. The cumulative DRT rate was 3.3% (95% CI: 2.0%-5.3%) with only 0.4% (95% CI: 0.1%-1.5%) deemed clinically relevant. One-year key clinical outcome rates are as follows: all-cause mortality: 3.9% (95% CI: 2.4%-6.3%); cardiovascular mortality: 1.9% (95% CI: 0.9%-3.8%); major bleeding: 6.6% (95% CI: 4.5%-9.2%); ischemic stroke or systemic embolism: 1.8% (95% CI: 0.8%-3.3%); pericardial effusion requiring intervention: 0.9% (95% CI: 0.3%-2.1%). No (0%) device embolization occurred. Median follow-up was 365 days (IQR: 349-380 days). CONCLUSIONS: The VERITAS study results support the 1-year safety and effectiveness of the next-generation device. (Abbott Medical-VERITAS Study; NCT06707688).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Left Atrial Appendage Occlusion with the Watchman FLX Device: A Single-Centre Retrospective Analysis of Procedural and One-Year Clinical Outcomes.Medical sciences (Basel, Switzerland) · 2026
- Left atrial appendage closure: Current status, unresolved issues, and future perspectivesCardiovascular Intervention and Therapeutics · 2025
- Left Atrial Appendage Occlusion vs Direct Oral Anticoagulants for Atrial Fibrillation: Network Meta-Analyses.JACC. Advances · 2026
- Left Atrial Appendage Occlusion Versus Oral Anticoagulation in Atrial Fibrillation: A Comprehensive Evidence Synthesis.Pacing and clinical electrophysiology : PACE · 2026
- Safety and Efficacy of Left Atrial Ablation After Percutaneous Left Atrial Appendage Occlusion in High-Bleeding-Risk Patients with Atrial Fibrillation: A Multicenter Analysis from the PROCEED-AF Ablation Registry.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Left Atrial Appendage Occlusion Versus NOACs in patients With Atrial Fibrillation: Rationale and Design of the CATALYST TrialAmerican Heart Journal · 2026