Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

Validated LC-MS/MS methods show acetyl-rimantadine is a superior biomarker of SAT1 activity compared to acetyl-amantadine for cancer applications.

Thordur Hendrickson-Rebizant, Wenxia Luo, Nur A Safa, Olufola O Ige, Amir Barzegar Behrooz, Daniel S Sitar, Rashid Ahmed Bux, Prasanta Paul,

Pharmaceutical Analysis Laboratory, College of Pharmacy, University of Manitoba, Winnipeg, MB R3E 0T5, Canada; Paul Albrechtsen Research Institute, CancerCare, Winnipeg, MB R3E 0V9, Canada. · Department of Pharmacology and Therapeutics, Rady Faculty of Health Sciences, Max Rady College of Medicine, University of Manitoba, Winnipeg, MB R3E 0T6, Canada.

Key points

From the paper's conclusion
  • Here we develop a validated, sensitive, accurate, and precise LC-MS/MS method for the quantification of Ac-Rim in urine and plasma as a biomarker, as well as detection methods for Ac-Rim and Ac-Aman in cell culture media for in-vitro discovery-based applications.

Abstract

Spermidine/spermine N1-acetyltransferase (SAT1) acetylates polyamines, to facilitate their metabolism. SAT1 expression is increased in some cancers making the analysis of its acetylated metabolites potentially useful as a biomarker for cancer. When highly expressed, SAT1 can acetylate the antivirals amantadine and rimantadine and these metabolites may be a better biomarker for SAT1 activity than the endogenous acetylated polyamines. Validated methods of quantification of Ac-Aman in urine and plasma have been developed as a biomarker for lung and breast cancer, but a validated method of analysis of Ac-Rim has yet to be developed. Here we develop a validated, sensitive, accurate, and precise LC-MS/MS method for the quantification of Ac-Rim in urine and plasma as a biomarker, as well as detection methods for Ac-Rim and Ac-Aman in cell culture media for in-vitro discovery-based applications. Analytes were separated using an Acquity UPLC BEH C18 column connected to a Nexera UHPLC and an 8040 triple quadrupole mass spectrometer (LC-MS/MS) (Shimadzu). Linearity was established from 15.63-1000 nM for Ac-Rim in cell medium and urine, 31.3 -1000 nM for Ac-Rim in plasma, and 5-10,000 nM for Ac-Aman in cell medium (all R2 > 0.99). All methods had minimal matrix effects from 95 to 114%, and recoveries ranged from 18 to 114%. When incubated with the glioblastoma cell line U-251, rimantadine produces >100-fold more Ac-Rim than amantadine does Ac-Aman. We show that SAT1 can acetylate amantadine and rimantadine in biochemical experiments where the enzyme produces >10-fold more Ac-Rim than Ac-Aman.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers