Feasibility of steerable sheath-guided left atrial appendage closure in challenging anatomy.
Sho Shiba, Masanori Yamamoto, Tatsuya Tsunaki, Ryo Yamaguchi
Department of Cardiology, Toyohashi Heart Center, Toyohashi, Aichi, Japan.
Key points
From the paper's conclusion- A bidirectional steerable sheath provides real-time control of the delivery axis and may prevent kick-back at release, enabling reproducible optimal device positioning in anatomically challenging LAAs where fixed-curve sheaths are inadequate.
Abstract
UNLABELLED: Percutaneous left atrial appendage closure (LAAC) is an established treatment option for stroke prevention in patients with non-valvular atrial fibrillation (NVAF) who are unsuitable for long-term oral anticoagulation. However, an anatomically challenging left atrial appendage (LAA) can limit optimal device positioning and complete occlusion with conventional fixed-curve sheaths.Two elderly men with NVAF and high bleeding risk underwent LAAC using Watchman FLX Pro devices (Boston Scientific, Marlborough, MA, USA). Pre-procedural imaging revealed anatomically challenging LAAs. With a standard double-curve sheath, one case showed unacceptable posterior protrusion of a large 40-mm device. In another case, tilting of the device led to incomplete coverage of the posterior lobe, resulting in a residual peri-device leak. After switching to the TruSteer™ Access System (Boston Scientific), a bidirectional steerable sheath, improved coaxial alignment, enabled acceptable device protrusion, complete sealing with no residual leak, and stable device release in both cases. These cases suggest that a steerable sheath can overcome the limitations of fixed-curve sheaths in anatomically challenging LAAs by enabling coaxial alignment and optimized posterior wall apposition during LAAC. LEARNING OBJECTIVE: In wide-neck, shallow, or multilobed left atrial appendages (LAAs), failure to meet PASS criteria with a conventional fixed-curve sheath may reflect non-coaxial deployment and, with very large devices, sheath instability due to kick-back at release, leading to device tilt. A bidirectional steerable sheath provides real-time control of the delivery axis and may prevent kick-back at release, enabling reproducible optimal device positioning in anatomically challenging LAAs where fixed-curve sheaths are inadequate.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of the combined technique of novel transseptal puncture guidewire and steerable sheath in left atrial appendage occlusion: a preliminary feasibility case series.Frontiers in cardiovascular medicine · 2026
- Left atrial appendage closure: Current status, unresolved issues, and future perspectivesCardiovascular Intervention and Therapeutics · 2025
- Left Atrial Appendage Closure: Past, Present, and Future.The Journal of innovations in cardiac rhythm management · 2026
- Persistent peri-device leak following left atrial appendage occlusion treated with hybrid coil- and plug-based closure: a case report.European heart journal. Case reports · 2026
- Percutaneous Closure of a Left Atrial Pseudoaneurysm After Left Atrial Appendage Closure.JACC. Case reports · 2026
- Left Atrial Appendage Closure: Between Imaging Precision and Uncertain Clinical Benefit.Journal of clinical medicine · 2026