Transfemoral bone-anchored limbs alter joint-load-line offset during walking.
Brecca M M Gaffney, Dan W Milius, Danielle H Melton, Cory L Christiansen, Jason W Stoneback
University of Colorado Bone-Anchored Limb Research Group, Aurora, CO, United States; Department of Mechanical Engineering, University of Colorado Denver, Denver CO, United States; Department of Biomedical Engineering, University of Colorado Anschutz Medical Campus, Aurora, CO, United States; Eastern Colorado Geriatric Research Education and Clinical Center, Aurora, CO, United States. Electronic address: brecca.gaffney@ucdenver.edu. · University of Colorado Bone-Anchored Limb Research Group, Aurora, CO, United States; Department of Orthopedics, University of Colorado School of Medicine, Aurora, CO, United States.
Key points
From the paper's conclusion- Our objective was to determine how the position of the GRF relative to hip and knee joint centers during walking differs between individuals with transfemoral amputation using either a socket prosthesis or bone-anchored limb (BAL).
Abstract
Individuals with transfemoral amputation are at a heightened risk of musculoskeletal overuse injuries and reduced stability, largely due to altered joint biomechanics. The position of the ground reaction force (GRF) relative to hip and knee joints directly influences both joint biomechanics and dynamic stability and is influenced both by both movement patterns and prosthetic alignment. However, it is unknown if it is influenced by prosthetic suspension type. Our objective was to determine how the position of the GRF relative to hip and knee joint centers during walking differs between individuals with transfemoral amputation using either a socket prosthesis or bone-anchored limb (BAL). Motion capture data was collected from a convenience sample of 17 participants with unilateral transfemoral amputation during overground walking at two timepoints: before and 12-months following BAL implantation. The distances between the GRF line of action and the hip and knee joints in the sagittal and frontal planes were calculated and compared across timepoints (α = 0.05). The distance between the GRF and hip joint center was less medial (p < 0.001) on the amputated limb and more lateral (p < 0.001) on the intact limb during stance period when using a BAL compared to a socket prosthesis. Closer positioning of the GRF relative to the hip joint may reduce frontal plane compensatory strategies required for hip stabilization, potentially reflecting a biomechanical stable gait pattern when using a BAL.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Residual femur motion during the stance phase of gait is associated with dynamic stability in individuals with transfemoral amputations.Clinical biomechanics (Bristol, Avon) · 2026
- Influence of the pelvic bone and gluteal zone over the stress state at the interaction between the prosthetic socket and residual limb for people with transfemoral amputation.Frontiers in bioengineering and biotechnology · 2026
- Effects of a Torsion-Adaptive Energy-Storing-and-Return Prosthetic Foot on Balance Control in Individuals with Transtibial Amputation: A Pilot Pre-Post Motion Analysis Study.Bioengineering (Basel, Switzerland) · 2026
- Medial knee loading responses to prosthetic foot stiffness during various ambulatory activities.Journal of biomechanics · 2026
- Propulsion-related gait characteristics in individuals using hip disarticulation prostheses.Gait & posture · 2026
- Sound-limb propulsive impulse after lower-limb amputation increases with amputation level but is not driven by peak ankle power.Journal of biomechanics · 2026