Quantifying digital volume correlation strain uncertainty at the bone-pedicle screw interface: an ex-vivo zero-strain analysis.
Léa Slive, Ye Young Shin, Martine McGregor, Stewart McLachlin, Jonathan Kusins
Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario, Canada. · Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada.
Key points
From the paper's conclusion- Toward improving pre-clinical assessment of pedicle screw fixation, this study combines micro-CT imaging, U-Net deep learning segmentation, and digital volume correlation (DVC) techniques to quantify the errors associated with measuring full-field strains at the screw-bone interface under nominal zero-strain conditions.
Abstract
Pedicle screws are essential for postoperative construct stability in spinal fusion surgeries. However, screw loosening remains a common clinical complication, often linked to excessive loading that induces damaging trabecular bone strains surrounding the pedicle screw. Toward improving pre-clinical assessment of pedicle screw fixation, this study combines micro-CT imaging, U-Net deep learning segmentation, and digital volume correlation (DVC) techniques to quantify the errors associated with measuring full-field strains at the screw-bone interface under nominal zero-strain conditions. Pedicle screws were surgically implanted into six human lumbar vertebrae specimens. Each specimen underwent micro-CT imaging. For three specimens, paired unloaded scans were acquired and analyzed using a standard DVC uncertainty workflow. To mitigate local bone-metal artifacts, bone segmentation was performed using a U-Net model, and segmentation accuracy was quantified using the Sørensen-Dice similarity coefficient. The U-Net model reproduced manual segmentations with high fidelity (average Dice = 0.94 ± 0.01). DVC accuracy and precision depended on the spatial resolution of strain measurement; at a DVC spatial resolution of 1.8 mm, strain estimates around the screw were reliable with low error (accuracy = 387 ± 110 µε; precision = 222 ± 82 µε). This study establishes the feasibility of a micro-CT-based DVC workflow and characterizes the strain measurement errors within trabecular bone surrounding pedicle screws using a zero-strain analysis. This workflow provides a foundation for future studies involving loaded tests, further optimization of segmentation to suppress artifacts, and validation across larger cohorts and implant designs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimising digital volume correlation across materials: a practical framework for accuracy and spatial resolutionbioRxiv · 2026
- Toward accurate regional lung strain quantification from microCT data: insights and limitations of digital volume correlation.Journal of the mechanical behavior of biomedical materials · 2026
- Prediction of Pedicle Screw Loosening For Lumbar Fusion Surgery With Preoperative Volume Of Interest-Based Hounsfield Units in Lumbar Vertebral Bodies On Computed TomographyClinical Spine Surgery A Spine Publication · 2026
- Automatic Vertebral Body Segmentation Performance in Lateral Thoracic Spine X-Rays: A Comparative Analysis Based on Implant Presence and Subtype.Journal of imaging informatics in medicine · 2026
- Predicting femoral neck screw pullout strength using DXA and novel assessments of bone microarchitecture.Archives of osteoporosis · 2026
- Pedicle screw loosening after degenerative lumbar fusion: a systematic review and meta-analysis of preoperative imaging-derived bone quality and paraspinal muscle metrics.Acta neurochirurgica · 2026