Predicting femoral neck screw pullout strength using DXA and novel assessments of bone microarchitecture.
Jarod Moyer, Richard Behlmer, Diane Krueger, Gretta Borchardt, Neil Binkley, Herman Feller, Sam Mosiman, Paul Whiting,
Department of Orthopedics & Rehabilitation, University of Wisconsin School of Medicine and Public Health, 1685 Highland Avenue, 6th Floor, Madison, WI, 53705, USA. jrmoyer2@wisc.edu. · Department of Orthopedics & Rehabilitation, University of Wisconsin School of Medicine and Public Health, 1685 Highland Avenue, 6th Floor, Madison, WI, 53705, USA.
Key points
From the paper's conclusion- Our findings highlight the clinical utility of hip-specific DXA as a strong and accessible predictor of screw pullout strength, performing as well as newer imaging modalities such as TBS Ortho and 3D-Shaper. Insertional torque also demonstrated strong predictive value and may serve as a useful intraoperative tool when preoperative bone density data are not available.
Abstract
UNLABELLED: This study determined how well DXA and other novel assessments of bone microarchitecture predicted screw pullout strength in the femoral neck. Hip-specific DXA performed as well as the novel approaches at predicting screw pullout. These findings support the use of DXA to evaluate bone quality and aid in surgical decision-making. PURPOSE: The primary purpose of our study was to determine how well dual-energy x-ray absorptiometry (DXA), trabecular bone score (TBS Ortho), 3D-Shaper, and quantitative computed tomography (qCT) predicted screw pullout of cannulated screws placed in the femoral neck of cadaveric specimens. Our secondary objective was to determine how well insertional torque predicted screw pullout. METHODS: We conducted a biomechanical study using twenty proximal cadaveric femurs. Each femur underwent imaging with each respective modality to assess bone quality. Screws were placed in a standardized configuration, and insertional torque was measured using a digital torque screwdriver. Screws were then pulled out using a mechanical testing machine to determine peak pullout strength. The relationship between screw pullout force and each bone metric was assessed using Spearman correlation coefficients and univariate linear mixed-effects models. RESULTS: DXA bone mineral density (BMD) and 3D-Shaper volumetric BMD (vBMD) at the femoral neck had the highest correlation coefficients with screw pullout strength (r = 0.95, p < 0.001). However, all of the imaging modalities were found to be strong predictors of screw pullout. Insertional torque was also a strong predictor of screw pullout strength (r = .86, p < 0.001). CONCLUSION: Our findings highlight the clinical utility of hip-specific DXA as a strong and accessible predictor of screw pullout strength, performing as well as newer imaging modalities such as TBS Ortho and 3D-Shaper. Insertional torque also demonstrated strong predictive value and may serve as a useful intraoperative tool when preoperative bone density data are not available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D-DXA-based Finite Element Models Improve Hip Fracture Prediction versus aBMD in the Japanese Population-Based Osteoporosis (JPOS) Cohort StudymedRxiv · 2026
- Pedicle screw loosening after degenerative lumbar fusion: a systematic review and meta-analysis of preoperative imaging-derived bone quality and paraspinal muscle metrics.Acta neurochirurgica · 2026
- The fixed cortical fraction assumption in Hip Structure Analysis produces systematic, sex- and age- dependent errors in femoral neck morphology estimates.Frontiers in endocrinology · 2026
- Preoperative vertebral fracture assessment reveals bone fragility missed by DXA in patients undergoing total hip arthroplasty.Arthroplasty (London, England) · 2026
- Cortical and trabecular deficits in patients with recent hip fractures assessed by DXA and 3D-DXA.Journal of bone and mineral metabolism · 2026
- Hip morphology and bone mineral density are associated with hip fracture type in elderly Japanese patients.Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association · 2026