Pacing Related Conduction Delay as an Indicator of Intramural Site of Origin of Focal Ventricular Arrhythmias.

Jeanne du Fay de Lavallaz, Mohammed Naji, Dakota De Cecco, Boldizsar Kovacs, Jackson J Liang, Michael Ghannam, Amrish Deshmukh, Kelly Arps,

Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan, USA. · Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan, USA. Electronic address: fbogun@med.umich.edu.

Key points

From the paper's conclusion
  • Conduction delay with matching PMs but late activation indicates a deeper SOO. A cutoff value of >26 milliseconds between S-QRS and EGM-QRS intervals identified deeper-seated VA target sites. This required further mapping to identify alternative ablation sites. A matching PM may not always be indicative of the SOO in patients with PVCs.

Abstract

BACKGROUND: The diagnosis of intramural focal ventricular arrhythmias (VA) can be challenging and is often made in retrospect after a long ineffective procedure. OBJECTIVES: In this cohort of patients, we aim to assess the value of pace-mapping (PM), stimulus-QRS interval (S-QRS interval), and electrogram (EGM)-QRS intervals to identify the site of origin (SOO) of focal VAs. METHODS: In a consecutive series of 46 patients with frequent premature ventricular complexes (PVCs), activation mapping and PM were performed to identify VA target sites. VA target sites were defined as sites with matching PM (≥10/12 leads) and/or sites with the earliest activation time. S-QRS interval and bipolar activation time at target sites were assessed and correlated with acute outcomes. If ablation at a target site failed, alternative sites were sought in adjacent anatomical structures. An intramural origin was defined as a VA with early activation time without a matching PM. RESULTS: Matching PMs were identified for 32 VAs in 30 of the 46 patients. Receiver operating characteristic analysis was performed at the target site/PVC level and demonstrated that a mismatch between S-QRS and EGM-QRS of >26 milliseconds distinguished effective from ineffective ablation sites with a matching PM (area under the curve: 0.98; 95% CI: 0.94-1; sensitivity: 100%; specificity: 88.9%). A mismatch was present in 9 patients, and radiofrequency ablation failed in 8/9 of them. Alternate sites with early activation times (-48.4 ± 37.39 milliseconds) without matching PM, where radiofrequency eliminated the PVCs, were identified in 5/8 patients. CONCLUSIONS: Conduction delay with matching PMs but late activation indicates a deeper SOO. A cutoff value of >26 milliseconds between S-QRS and EGM-QRS intervals identified deeper-seated VA target sites. This required further mapping to identify alternative ablation sites. A matching PM may not always be indicative of the SOO in patients with PVCs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers