Intra-Aortic Balloon Pump Bridging to Delayed Valve Surgery After Leaflet Injury During Transcatheter Edge-to-Edge Repair.
Lennart Henry Muras, David Hirschl, Matthias Heringlake, Alexander Kaminski, Simon Schemke
Department of Anesthesiology and Intensive Care Medicine, Heart and Diabetes Center Mecklenburg-Western Pomerania, Karlsburg Hospital, Karlsburg, Germany. Electronic address: lennart@muras.de. · Department of Anesthesiology and Intensive Care Medicine, Heart and Diabetes Center Mecklenburg-Western Pomerania, Karlsburg Hospital, Karlsburg, Germany.
Key points
From the paper's conclusion- The patient was stabilized with an intra-aortic balloon pump and underwent successful delayed mitral valve replacement and tricuspid valve repair 4 days later.
Abstract
BACKGROUND: Mitral leaflet injury during transcatheter edge-to-edge repair (TEER) is a rare complication that may result in severe mitral regurgitation requiring emergency surgery. Evidence on temporary mechanical circulatory support as a bridge to surgery in this setting is limited. CASE SUMMARY: A 75-year-old woman with advanced nonischemic cardiomyopathy and severe functional mitral regurgitation underwent TEER complicated by injury of both mitral leaflets, resulting in torrential mitral regurgitation and progressive hemodynamic deterioration. Immediate surgery was deferred because of recent apixaban exposure and associated bleeding risk. The patient was stabilized with an intra-aortic balloon pump and underwent successful delayed mitral valve replacement and tricuspid valve repair 4 days later. DISCUSSION: Aortic counterpulsation can provide effective hemodynamic support in selected patients with acute severe mitral regurgitation after failed TEER without escalation to more invasive mechanical circulatory support and in this case facilitated successful bridging of a high-risk patient to surgery. Moreover, this case highlights that in nonemergent patients scheduled for TEER, anticoagulation therapy should be appropriately stopped before the intervention to allow either surgical conversion or optimal management in case of severe bleeding.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Parallel Septal Balloon Occlusion for Acute Right-to-Left Shunt During Mitral Transcatheter Edge-to-Edge Repair.JACC. Case reports · 2026
- Vascular Plug Closure of Delayed Leaflet Perforation Post-TEER in Patient With Multiple Implantable Devices.JACC. Case reports · 2026
- Transcatheter Mitral Valve-in-Valve Implantation Despite Left Atrial Appendage Thrombosis: A Challenging Therapeutic Strategy.JACC. Case reports · 2026
- Ultra-Early Transcatheter Edge-to-Edge Repair Intervention With Mechanical Circulatory Support for Post-Infarction Papillary Muscle Rupture.JACC. Case reports · 2026
- Combined veno-venous ECMO and direct aortic impella 5.5 support enabling emergency mitral valve replacement in acute severe mitral regurgitation with fulminant pulmonary edema.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2026
- Prevention of Left Ventricular Outflow Tract Obstruction During High-Risk Transcatheter Mitral Valve Replacement.JACC. Case reports · 2026