Vascular Plug Closure of Delayed Leaflet Perforation Post-TEER in Patient With Multiple Implantable Devices.
Guanzhong Chen, Zhenyu Xiong, Menghui Liu, Ziwei Zhou, Jiantong Shen, Min Ye, Fengjuan Yao, Xinxue Liao,
Department of Cardiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China; NHC Key Laboratory of Assisted Circulation and Vascular Diseases, Sun Yat-sen University, Guangzhou, China. · Department of Cardiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China; Department of Anesthesiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Key points
From the paper's conclusion- A 63-year-old man with multivalvular heart disease, chronic heart failure, multiple implantable devices and dialysis-dependent end-stage renal disease presented with symptomatic severe recurrent MR secondary to delayed anterior mitral leaflet perforation after TEER.
Abstract
BACKGROUND: Transcatheter edge-to-edge repair (TEER) is the main minimally invasive therapy for severe mitral regurgitation (MR) in patients at high surgical risk. Roughly 10% of patients develop recurrent MR within 1 year postoperatively. Postprocedural mitral anatomical distortion complicates reintervention, rendering recurrent MR management a common clinical challenge. CASE SUMMARY: A 63-year-old man with multivalvular heart disease, chronic heart failure, multiple implantable devices and dialysis-dependent end-stage renal disease presented with symptomatic severe recurrent MR secondary to delayed anterior mitral leaflet perforation after TEER. Under combined fluoroscopic and 3-dimensional transesophageal echocardiographic guidance, our multidisciplinary team performed transcatheter closure of the perforation using a vascular plug. MR was markedly alleviated, heart failure symptoms resolved, and the patient recovered uneventfully before discharge. DISCUSSION: TEER-related leaflet perforation caused severe recurrent MR. Percutaneous plug closure successfully downgraded MR to trivial, confirming the feasibility of this approach for mitral leaflet perforation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Snare-Assisted Retrieval of a Mechanically Locked-Open TEER Device: A Novel Bailout Technique.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Transcatheter Edge-to-Edge Repair of Mitral Valve Leaflet Perforation Guided by 3D Multiplanar Reconstruction Imaging.JACC. Case reports · 2026
- Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Novel Transcatheter Edge-to-Edge Repair System for High-Risk Primary Mitral RegurgitationJACC Asia · 2026
- Durability of Mitral Valve Transcatheter Edge-to-Edge RepairJACC: Cardiovascular Interventions · 2026
- Persistent Severe Tricuspid Regurgitation After Mitral Transcatheter Edge-to-Edge Repair: Prognostic Implications of Guideline-Based Eligibility for Transcatheter Tricuspid Valve InterventionStructural Heart · 2026