Successful M-TEER Using Curved Laryngoscope-Assisted, Endoscopy-Guided TEE Insertion in a Patient With Esophageal Diverticulum.
Hiroko Hasegawa, Kenichi Sakakura, Yoshihiko Chiba, Takaya Miura, Masami Suzuki, Homare Okamura, Hideo Fujita
Division of Cardiovascular Medicine, Jichi Medical University Saitama Medical Center, Saitama, Japan. Electronic address: h-hiroco2@jichi.ac.jp. · Division of Cardiovascular Medicine, Jichi Medical University Saitama Medical Center, Saitama, Japan.
Key points
From the paper's conclusion- After multidisciplinary discussion, endoscopically guided TEE probe insertion using a Sato's curved laryngoscope (Nagashima Medical Instruments Co, Ltd) enabled safe advancement into the esophageal lumen while avoiding the diverticulum.
Abstract
BACKGROUND: Real-time 3-dimensional transesophageal echocardiography (TEE) is indispensable for mitral transcatheter edge-to-edge repair (M-TEER), but Zenker's diverticulum is generally considered a contraindication because of the risk of esophageal perforation. CASE SUMMARY: A 78-year-old woman with symptomatic severe ventricular functional mitral regurgitation despite optimal medical therapy was referred for M-TEER. Preprocedural evaluation revealed a Zenker's diverticulum, making blind TEE probe insertion unsafe. After multidisciplinary discussion, endoscopically guided TEE probe insertion using a Sato's curved laryngoscope (Nagashima Medical Instruments Co, Ltd) enabled safe advancement into the esophageal lumen while avoiding the diverticulum. M-TEER was successfully completed under real-time 3-dimensional TEE guidance without complications. DISCUSSION: This case demonstrates a novel approach to TEE-guided structural heart interventions in a patient with Zenker's diverticulum, generally considered unsuitable for TEE. TAKE-HOME MESSAGES: Challenging gastrointestinal anatomy should not necessarily preclude TEE-guided structural heart interventions. Endoscopic TEE probe insertion assisted by Sato's curved laryngoscope may safely overcome this anatomical challenge in selected patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D Intracardiac Echocardiography-Guided Mitral M-TEER for a Challenging Medial P3 Flail in Patient With Esophagectomy.JACC. Case reports · 2026
- Transcatheter Edge-to-Edge Mitral Valve Repair Through a Native Atrial Septal Defect: An Anatomy-Guided Strategy.JACC. Case reports · 2026
- Parallel Septal Balloon Occlusion for Acute Right-to-Left Shunt During Mitral Transcatheter Edge-to-Edge Repair.JACC. Case reports · 2026
- Intervention time represents an independent predictor for esophageal lesions during M-TEER and T-TEER proceduresEuropean Heart Journal · 2026
- Snare-Assisted Retrieval of a Mechanically Locked-Open TEER Device: A Novel Bailout Technique.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Leaflet Perforation During Mitral Transcatheter Edge-to-Edge Repair: A Stepwise Dual-Device Strategy Leveraging Valve Geometry Modification.JACC. Case reports · 2026