JACC. Case reports

Miniaturizing Slipstream and Tip Detection to a 7-F Transradial System for Chronic Total Occlusion PCI.

Masataka Yoshinaga, Kenya Nasu, Keisuke Murata, Toru Araki, Kouki Matsuo, Akane Miyazaki, Takehiro Ito, Yoshihiro Sobue,

Department of Cardiology, Fujita Health University Bantane Hospital, Nagoya, Aichi, Japan. Electronic address: yoshinaga.mm1021@gmail.com. · Department of Cardiology, Mie Heart Center, Meiwa, Mie, Japan.

Key points

From the paper's conclusion
  • Miniaturizing slipstream and tip detection to a 7-F system provides a smaller radial access footprint for complex CTO percutaneous coronary intervention while preserving advanced IVUS-guided wiring.

Abstract

OBJECTIVE: To demonstrate that the combination of the slipstream and tip detection can be miniaturized to a 7-F radial system using the SIDEPASS short-monorail dual-lumen catheter and AnteOwl intravascular ultrasound (IVUS) for a chronic total occlusion (CTO) lesion. KEY STEPS: Treat the in-stent restenosis in left circumflex artery #14 and insert the AnteOwl IVUS over the same wire (first-wire lumen only) to delineate the spatial relationship between the stent struts and the jailed ostium of left circumflex artery #15 CTO. Advance the SIDEPASS short-monorail dual-lumen catheter over the same wire within a 7-F guiding catheter, pass a second guidewire through an optimal stent-strut cell into the CTO, and complete lesion preparation. POTENTIAL PITFALLS: Narrow clearance within a 7-F guide, first-wire instability when removing the dual-lumen catheter, and inaccurate ostium identification can hinder the procedure. TAKE-HOME MESSAGES: Miniaturizing slipstream and tip detection to a 7-F system provides a smaller radial access footprint for complex CTO percutaneous coronary intervention while preserving advanced IVUS-guided wiring.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers