Endoaortic Balloon Occlusion for Minimally Invasive Mitral Valve Replacement After Previous Balloon-Expandable TAVI.
Giulia Agostini, Cristina Barbero, Gaia Andrea Galanti, Laura La Montagna, Francesca Ciancamerla, Michele William La Torre, Stefano Salizzoni, Mauro Rinaldi
Cardiac Surgery Division, Department of Surgical Sciences, City of Health and Science University Hospital, University of Turin, Turin, Italy. Electronic address: giulia.agostini@unito.it. · Cardiac Surgery Division, Department of Surgical Sciences, City of Health and Science University Hospital, University of Turin, Turin, Italy.
Key points
From the paper's conclusion- A 56-year-old woman with radiation-induced multivalvular disease underwent staged transfemoral balloon-expandable TAVI and coronary revascularization, followed by minimally invasive mitral valve replacement using EABO.
Abstract
BACKGROUND: Prior transcatheter aortic valve implantation (TAVI) may complicate minimally invasive mitral valve surgery when endoaortic balloon occlusion (EABO) is considered. Guidance for EABO after TAVI remains limited. CASE SUMMARY: A 56-year-old woman with radiation-induced multivalvular disease underwent staged transfemoral balloon-expandable TAVI and coronary revascularization, followed by minimally invasive mitral valve replacement using EABO. Pre-TAVI computed tomography identified a potential ascending-aortic landing zone, and continuous TEE confirmed balloon positioning above the TAVI frame. EABO achieved complete aortic occlusion without migration, frame contact, or evidence of cerebral malperfusion. DISCUSSION: Prior balloon-expandable TAVI may not preclude EABO in carefully selected patients with favorable ascending-aortic anatomy. Imaging-based selection, continuous TEE surveillance, and controlled inflation are central to safety. TAKE-HOME MESSAGE: Prior balloon-expandable TAVI does not preclude EABO in selected patients with a suitable ascending-aortic landing zone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transcatheter Mitral Valve Replacement in an Incomplete Ring With LAMPOON Facilitated By Aortic Prosthesis.JACC. Case reports · 2026
- Feasibility and Procedural Considerations of Balloon-Expandable TAVR in Patients With Prior Endovascular Aortic Stent Grafts.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Efficacy and Safety of Routine Postdilation in Balloon-Expandable Transcatheter Aortic Valve Implantation Platform: The DUOTAP Randomized Clinical Trial.JAMA cardiology · 2026
- TAV-in-TAV-in-SAV in a Patient With Prior Mitral Valve-in-Valve.JACC. Case reports · 2026
- Prosthesis-to-Prosthesis Balloon Interaction During TAVR Causing Aorto-Mitral Curtain Injury and Left Ventricular Pseudoaneurysm.JACC. Case reports · 2026
- Expanding TMVR Suitability with a Transseptal Left Atrial Fixation Device: A CT-based Eligibility AnalysisEuropean Heart Journal · 2026