Multisite Peripheral Photoplethysmography Captures Intra-Aortic Balloon Pump Counterpulsation and Weaning State in Cardiogenic Shock.
Koki Nakada, Timothy Burton, Faraz Sadrzadeh-Afsharazar, Hiroya Chiba, Alexandre Douplik, Tasuku Matsuyama, Gennadi Saiko
Department of Emergency Medicine, Kyoto Prefectural University of Medicine, Kyoto, Japan; Department of Emergency and Critical Care Medicine (ICU), Otsu City Hospital, Otsu, Shiga, Japan. · Department of Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada.
Key points
From the paper's conclusion- Ordinary peripheral PPG carries a beat-resolved signature of IABP counterpulsation and of the weaning course, without vascular access.
Abstract
BACKGROUND: Intra-aortic balloon pump (IABP) counterpulsation raises aortic diastolic pressure every cycle (1:1) or alternate cycles (1:2, weaning). Whether they reach peripheral photoplethysmography (PPG) is unknown; 1 report described 1:1 only. CASE SUMMARY: An 82-year-old man in IABP-supported cardiogenic shock had finger and thenar PPG on 1:1, 1:2, removal, and twice afterward. An augmented diastolic peak appeared on every finger beat on 1:1 and alternate beats on 1:2, barring ectopy, and none afterward. Perfusion index reached a nadir at removal and rose through recovery; finger-thenar coherence followed a similar trend. DISCUSSION: Peripheral PPG encoded assist ratio and weaning state. The augmented peak was proportionally larger at the finger than in the aorta, raising the hypothesis that it reflects root- and arch-supplied territories. TAKE-HOME MESSAGE: Ordinary peripheral PPG carries a beat-resolved signature of IABP counterpulsation and of the weaning course, without vascular access.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Aortic Pulsatility Index Predicts Native Recovery in Patients With Cardiogenic Shock Supported by Intra-aortic Balloon PumpsJournal of Cardiac Failure · 2025
- Impact of intra-aortic balloon pump support on cerebral blood flow velocity during venoarterial ECMO.Journal of critical care · 2026
- Usefulness of the Current of Injury Function in a Pacing System Analyzers for Left Bundle Branch Area Pacing Implantation : A Case Report.Indian pacing and electrophysiology journal · 2026
- A Novel Cluster-Based Approach for PPG Signal Preprocessing: Motion Artifact Filtering and Ambient Light Correction.Sensors (Basel, Switzerland) · 2026
- Impella Versus Intra-aortic Balloon Pump in Cardiogenic Shock: Arrhythmias, Bleeding Complications, and In-Hospital Outcomes in a Propensity-Matched Analysis of the National Inpatient Sample.Cureus · 2026
- From Catheters to Wearables: Advanced Hemodynamic Monitoring and the Emerging Role of PPG-Based Devices.Cardiology research and practice · 2026