From Catheters to Wearables: Advanced Hemodynamic Monitoring and the Emerging Role of PPG-Based Devices.
Emil Aliev, Arik Eisenkraft, Dean Nachman
Hadassah Medical Center and Faculty of Medicine Heart Institute Hebrew University of Jerusalem Jerusalem Israel huji.ac.il. · Department of Military Medicine Faculty of Medicine Institute for Research in Military Medicine The Hebrew University of Jerusalem Jerusalem Israel huji.ac.il.
Key points
From the paper's conclusion- Further multicenter, outcome‐oriented studies are required to establish the clinical role of PPG‐based devices across diverse patient populations and stages of care.
Abstract
Advanced hemodynamic monitoring, including cardiac output (CO), stroke volume (SV), and systemic vascular resistance (SVR), is important for the management of cardiogenic shock, postoperative patients, and heart failure. Traditional approaches such as pulmonary artery catheterization (PAC) provide comprehensive hemodynamic assessment but are invasive, costly, and associated with procedure-related risks. This review summarizes established invasive and minimally invasive techniques alongside emerging noninvasive approaches, including pulse contour analysis, bioimpedance, pulse wave transit time, and photoplethysmography (PPG)-based systems. Particular emphasis is placed on PPG-based technologies, which combine pulse wave analysis, pulse wave transit time, and advanced signal processing to estimate blood pressure and flow-related parameters. As a representative case study, the clinical development and evaluation of the Biobeat BB-613WP wearable are described, including preclinical swine hemorrhagic shock models, intensive care and perioperative validation against invasive reference methods, and ambulatory blood pressure monitoring studies. Available evidence suggests that PPG-based wearables can achieve clinically acceptable agreement with invasive reference methods in selected populations while offering the potential for continuous, noninvasive, and ambulatory monitoring. However, the available evidence is limited by small sample sizes, single-center studies, controlled conditions, and limited independent validation. Further multicenter, outcome-oriented studies are required to establish the clinical role of PPG-based devices across diverse patient populations and stages of care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical TranslationarXiv · 2026
- Clinical testing of software and medical devices based on photople-thysmography (PPG) sensors: a scoping review.Expert review of medical devices · 2026
- Development and validation of an integrated wearable system for continuous cardiorespiratory monitoring using photoplethysmography and optical respiratory detection.Medical & biological engineering & computing · 2026
- Clinical Readiness of Hemodynamic Estimation from Cardiac Vibration Signals: An Endpoint-Specific Critical Review.Annals of biomedical engineering · 2026
- A narrative review of methods for estimating blood pressure waveforms from photoplethysmography.Journal of clinical monitoring and computing · 2026
- Accuracy of Photoplethysmography-Derived Pulse Rate Variability Compared with Electrocardiography-Derived Heart Rate Variability: A Systematic Review and Meta-Analysis.Sensors (Basel, Switzerland) · 2026