Atrial Septal Defect Repair After Reverse Potts Shunt for Severe Pulmonary Hypertension.
Paighton C Miller, Jacob R Miller, David T Balzer, R Mark Grady, Pirooz Eghtesady
Section of Pediatric Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, St. Louis Children's Hospital, St. Louis, Missouri, USA. · Division of Pediatric Cardiology, Department of Pediatrics, Washington University School of Medicine, St. Louis Children's Hospital, St. Louis, Missouri, USA.
Key points
From the paper's conclusion- Atrial septal defect (ASD) closure in the presence of a functioning reverse Potts shunt (rPS) for pulmonary hypertension (PH) may reduce global hypoxemia without sacrificing right ventricular pressure unloading.
Abstract
BACKGROUND: Atrial septal defect (ASD) closure in the presence of a functioning reverse Potts shunt (rPS) for pulmonary hypertension (PH) may reduce global hypoxemia without sacrificing right ventricular pressure unloading. However, intracardiac operation after rPS has not previously been reported to guide operative decision-making in this scenario. CASE SUMMARY: A 13-year-old girl with a history of rPS for PH presented for ASD closure because of hypoxia and exercise intolerance. To safely close the ASD on cardiopulmonary bypass, the rPS was occluded with a catheter-based balloon. DISCUSSION: Coexisting ASD and rPS in a patient with severe PH presents a complex hemodynamic scenario. Furthermore, intracardiac operation in the setting of patent rPS and PH presents certain technical challenges. Multidisciplinary care is necessary for safe and effective management of coexisting ASD and rPS. TAKE-HOME MESSAGE: Balloon occlusion of reverse Potts shunt can be safely performed in select patients to expand feasibility for repair of intracardiac defects in PH.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transcatheter Sinus Venosus ASD Closure in Severe Pulmonary Hypertension.JACC. Case reports · 2026
- Percutaneous closure of an iatrogenic left atrial-aortic perforation complicated by cardiac tamponade and coronary vasospasm during transseptal puncture: a case report.BMC cardiovascular disorders · 2026
- Clinical Outcomes of Patients With Atrial Septal Defect and Pulmonary Arterial Hypertension.World journal for pediatric & congenital heart surgery · 2026
- Parallel Septal Balloon Occlusion for Acute Right-to-Left Shunt During Mitral Transcatheter Edge-to-Edge Repair.JACC. Case reports · 2026
- First Reported Concomitant Pulsed-Field Ablation and Left Atrial Appendage Occlusion in a Patient With Prior Atrial Septal Defect Closure Device.Cureus · 2026
- Off-Pump Retrieval of Patent Ductus Arteriosus Closure Device Causing Partial Aortic Obstruction.JACC. Case reports · 2026