Balloon-Augmented Bicuspid Scallop Intentional Laceration to Induce Circularization of the Aortic Implant (BA-BISILICA) During TAVR.
Vahe Shahmoradi, Vishal N Shah, Gabriel E Shaya, Esra Gucuk Ipek, Jeremy D Rier, James E Harvey, Rhian E Davies, Jae Yoon Park,
WellSpan Heart and Vascular Institute, WellSpan York Hospital, York, Pennsylvania, USA. · WellSpan Heart and Vascular Institute, WellSpan York Hospital, York, Pennsylvania, USA; Laboratory of Cardiovascular Intervention, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA. Electronic address: cbruce3@wellspan.org.
Key points
From the paper's conclusion- Transcatheter electrosurgical leaflet laceration may facilitate uniform THV expansion in Sievers type 1 bicuspid aortic valve patients undergoing transcatheter aortic valve replacement.
Abstract
OBJECTIVE: Sievers type 1 bicuspid aortic valve anatomy, characterized by a calcified raphe, eccentric calcification, and elliptical annular geometry, may impede complete transcatheter heart valve (THV) expansion during transcatheter aortic valve replacement. A stepwise transcatheter electrosurgical leaflet-laceration technique is described to optimize THV deployment. KEY STEPS: Cerebral embolic protection is established. A steerable guiding system is positioned adjacent to the calcified raphe. An electrified guidewire is used to traverse the fused leaflet. Balloon augmentation is performed. A "flying V" rail configuration is created. Electrosurgical raphe laceration is performed. The THV is deployed. PITFALLS: Pitfalls include embolization of calcium, difficulty lacerating a heavily calcified raphe, and hemodynamic instability. Technical tips include cerebral embolic protection, precise positioning of the traversal system adjacent to the raphe, balloon dilatation of the traversal channel, and prompt THV deployment. TAKE-HOME MESSAGE: Transcatheter electrosurgical leaflet laceration may facilitate uniform THV expansion in Sievers type 1 bicuspid aortic valve patients undergoing transcatheter aortic valve replacement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bicuspid Aortic Valve Leaflet Modification Before Transcatheter Aortic Valve ReplacementJACC Advances · 2026
- First-in-Human Mechanical Bilateral Iatrogenic Coronary Leaflet Obstruction Risk Nullification (BICORN) for Transcatheter Aortic Valve-in-Valve Replacement.JACC. Case reports · 2026
- Electrosurgical Leaflet Modification to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement in Failing Native and Bioprosthetic ValvesJACC: Cardiovascular Interventions · 2025
- Transcatheter aortic valve implantation in bicuspid aortic valve regurgitation: a case report.Journal of cardiothoracic surgery · 2026
- First Report of Antegrade Transeptal Valve-in-Valve TAVR: Revisiting an Old Strategy.JACC. Case reports · 2026
- TAV-in-TAV-in-SAV in a Patient With Prior Mitral Valve-in-Valve.JACC. Case reports · 2026