科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ JACC. Case reports2026-09-16

Radiation Dose Optimization in Coronary CT Angiography: A Quality Improvement Initiative.

Muhammad Kashif, Danish Waris Ali, Adeel Ur Rahman Siddiqui, Muhammad Ali, Sumair Ahmed, Muhammad Arshad, Bashir Hanif

原始摘要(英文原文)· Original abstract
BACKGROUND: Coronary computed tomography angiography (CCTA) is increasingly used for the evaluation of coronary artery disease; however, radiation exposure remains a patient safety concern. Data on radiation dose optimization from low- and middle-income countries are limited. PROJECT RATIONALE: Tabba Heart Institute Karachi identified opportunities to reduce CCTA radiation exposure through implementation of heart rate and body mass index-guided acquisition protocols while maintaining image quality. PROJECT SUMMARY: A quality improvement initiative was implemented using patient-specific scanning protocols. A total of 422 CCTA examinations were evaluated, including 117 preintervention and 305 postintervention studies. Median effective radiation dose decreased by 45.5%, from 8.8 mSv to 4.8 mSv (P < 0.001). CCTA dose-length product decreased by 46.5% and total dose-length product by 39.8% (both P < 0.001). No significant differences were observed in image quality metrics or repeat scan rates. TAKE-HOME MESSAGE: Technologist-driven protocol optimization can substantially reduce CCTA radiation exposure without compromising image quality and may serve as a scalable model for cardiovascular imaging programs in resource-constrained settings.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Radiation Dose Optimization in Coronary CT Angiography: A Quality Improvement Initiative. — 科研速览 Science Skim