Robust fractional hybrid controller for frequency regulation in nonlinear multi-area power systems amid communication delay and cyber-attack.
Zafar Ayub Ansari, Mohammed Hasmat Ali, Yogendra Arya, G Lloyds Raja
Department of Electrical Engineering, National Institute of Technology Patna, Ashok Rajpath, Patna, Bihar, 800005, India; Department of Electrical and Electronics Engineering, Loknayak Jai Prakash Institute of Technology (LNJPIT), Chapra, Bihar, India. Electronic address: zafara.ph21.ee@nitp.ac.in. · Department of Electrical Engineering, Integral University, Lucknow, U.P., 226026, India. Electronic address: mohammeda.phd19.ee@nitp.ac.in.
Key points
From the paper's conclusion- A unified controller tuning strategy is employed across all operating scenarios, including the IEEE 39-bus and Kundur 11-bus test systems.
Abstract
The digitalization of modern power systems (PSs) has transformed conventional grids into cyber-physical systems, increasing their vulnerability to communication delays and signal disturbances. This paper proposes a Flow Direction Algorithm (FDA)-optimized one-plus-tilt derivative cascaded with a fractional-order integral-derivative ((1+TD)-IλDμ) controller for robust load frequency control of nonlinear renewable-integrated PSs. The cascaded fractional-order structure enhances tuning flexibility and robustness against communication delays and signal perturbations. Rather than detecting cyber-attacks (CAs), the proposed controller is evaluated under false data injection (FDI), denial-of-service (DoS) attacks, random communication delays, and hybrid CAs using multiple benchmark PS models. A unified controller tuning strategy is employed across all operating scenarios, including the IEEE 39-bus and Kundur 11-bus test systems. Stability is verified through the Lyapunov-Krasovskii functional (LKF)-linear matrix inequality (LMI) framework, while controller-in-the-loop (CIL) experiments confirm the controller's practical feasibility and real-time applicability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Load Frequency Control of Multi-Area Power System Using Hybrid Fuzzy Tilt Integral with Tilt Integral Derivative-Based Fractional Order ControllerAlgorithms · 2026
- Robust fractional-order control design for LFC in interconnected power systems with RESsInternational Journal of Systems Science · 2026
- Resilient Load Frequency Control of Fractional-Order Power Systems Against DoS Attacks: A Commensurate SMC ApproachFractal and Fractional · 2026
- An Intelligent Hybrid PIDF Enhanced by a Fuzzy Fractional-Order Controller for Robust Load Frequency Regulation in a Two-Area Interconnected Power SystemEnergies · 2026
- A reinforcement learning-cooperated dynamic controller parameter optimisation for frequency control in a nonlinear power systemInternational Journal of Systems Science · 2026
- Optimal fractional order PID-load frequency controller for multi-interconnected microgrids including renewable energy and storage systemScientific Reports · 2026