PVI Using the Fixed Loop PFA in Paroxysmal AF: One-Year Outcomes with Continuous Implantable Loop Recorder Monitoring.

Sandeep K Goyal, Michael Hoosien, Ashish Bhimani

Piedmont Heart Institute, Atlanta, Georgia, USA. Electronic address: Sandeep.Goyal@Piedmont.org. · Piedmont Heart Institute, Atlanta, Georgia, USA.

Observational

Key points

From the paper's conclusion
  • In a PAF cohort with mandatory continuous rhythm monitoring, the PulseSelect™ system using a standardized workflow achieved universal acute PVI and favorable 12-month arrhythmia-free outcomes with an excellent safety profile. Continuous monitoring provides the most rigorous assessment of freedom from recurrence.

Abstract

INTRODUCTION/OBJECTIVES: Pulsed field ablation (PFA) is a promising non-thermal energy modality for pulmonary vein isolation (PVI) in atrial fibrillation (AF), with favorable safety and efficacy data. However, published data rely on intermittent rhythm monitoring, which likely underestimates recurrence rates. We sought to evaluate 12-month outcomes of PVI using the PulseSelect™ system in patients with paroxysmal AF (PAF) monitored continuously with implantable loop recorders (ILRs), and to characterize the performance of a standardized "6-4" lesion delivery workflow. METHODS: This is a single-center, prospective observational study of consecutive patients aged <75 years with symptomatic, PAF and an ILR. All ablations were performed using the PulseSelect™ catheter using a standardized workflow delivering 6 antral and 4 ostial PFA applications per pulmonary vein (PV), guided by left-sided intracardiac echocardiography. The primary endpoint was freedom from atrial tachyarrhythmias from 91 to 365 days post-ablation, assessed by continuous ILR. RESULTS: Twenty-five patients (13 male, 12 females; mean age 68.3 ± 4.2 years; CHA2DS2-VASc 2.5 ± 0.6) underwent PVI between August and November 2024. Acute PVI was achieved in 100% of PVs. Median procedure and left atrial dwell times were 74 (IQR 48-82) and 44 (IQR 34-57) minutes, respectively. Mean fluoroscopy time was 3.2 ± 1.7 minutes. At 12 months, freedom from atrial tachyarrhythmias off class I/III antiarrhythmic drugs was observed in 22 of 25 patients (88%). CONCLUSIONS: In a PAF cohort with mandatory continuous rhythm monitoring, the PulseSelect™ system using a standardized workflow achieved universal acute PVI and favorable 12-month arrhythmia-free outcomes with an excellent safety profile. Continuous monitoring provides the most rigorous assessment of freedom from recurrence.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers